MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2023.05.057

Медицинская библиотека · The American journal of cardiology · 2023

Comparison of Drug-Coated Balloon and Drug-Eluting Stent for the Treatment of Small Vessel Disease (from the Dissolve SVD Randomized Trial).

Liu Shengwen, Zhou Yujie, Shen Zhujun, Chen Hui, Qiu Chunguang, Fu Guosheng, Li Hui, Yu Zaixin, Zeng Qiutang, Li Zhanquan, Li Wei, Qiao Shubin, Dissolve SVD investigators

Рандомизированное исследованиеМногоцентровое исследованиеСтатьяEquivalence TrialПеревод пока не подготовлен

Аннотация

The Dissolve drug-coated balloons (DCBs) is a new-generation DCB coated with paclitaxel of balloon surface, with midchain triglyceride excipient. Although the use of DCBs is a promising technique, little is known about the the clinical efficacy of the novel Dissolve DCB in coronary small vessel disease. This study was a prospective, randomized, multicenter, noninferiority trial comparing the Dissolve DCB with the Resolute drug-eluting stent (DES) in patients with a reference vessel diameter ≥2.25 and ≤2.75 mm. Patients with a reference vessel diameter ≥2.00 and <2.25 mm were enrolled in the very small vessel registry. The angiographic and clinical follow-up were planned at 9 months and 1 year in all patients, respectively. The primary end point was 9-month in-segment percentage diameter stenosis. A total of 247 patients with small vessel disease from 10 Chinese sites were included (Dissolve DCB, n = 118; Resolute DES, n = 129); 30 patients were treated with the DCB in the very small vessel cohort. The 9-month in-segment percentage diameter stenosis was 31.2 ± 2.0% with Dissolve DCB versus 26.1 ± 2.1% with Resolute DES; the 1-sided 97.5% upper confidence limit of the difference was 10.3% (p for noninferiority = 0.0002). At 12 months, the DCB and DES groups were associated with similar rates of target lesion failure (8.5% vs 6.1%, p = 0.28) and major adverse cardiac and cerebrovascular events (20.9% vs 13.6%, p = 0.12). In conclusion, the Dissolve DCB was noninferior to the Resolute DES for the primary end point of 9-month in-segment percentage diameter stenosis in this multicenter, head-to-head, randomized trial (a safety and efficacy study of Dissolve In Treatment Of Coronary Small Vessel Disease; NCT03376646).

Для цитирования: Liu Shengwen, Zhou Yujie, Shen Zhujun, Chen Hui, Qiu Chunguang, Fu Guosheng, Li Hui, Yu Zaixin, Zeng Qiutang, Li Zhanquan, Li Wei, Qiao Shubin, Dissolve SVD investigators. Comparison of Drug-Coated Balloon and Drug-Eluting Stent for the Treatment of Small Vessel Disease (from the Dissolve SVD Randomized Trial).. The American journal of cardiology. 2023. DOI: 10.1016/j.amjcard.2023.05.057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.