MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.30886

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2023

Impact of prolonged drug-coated balloon inflation on residual stenosis and clinical outcomes in coronary artery disease patients: A propensity score matched analysis.

Ueda Hiroshi, Fujiwara Yoshihiro, Nishida Yusuke, Maenaka Motoyoshi, Yoshimura Kojiro, Oshida Yuki, Matsuhisa Seiji, Yoshida Naohiro, Yoshitani Hidetoshi, Kuga Yukiko, Ueda Kazuya, Nishida Yasunori

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

There is a paucity of data regarding the optimal duration of drug-coated balloon (DCB) inflation for coronary lesions. We sought to explore the effect of DCB angioplasty with versus without long inflation time on residual stenosis and clinical outcomes in patients with coronary artery disease.

METHODS

This study included 314 consecutive patients with 445 lesions undergoing paclitaxel DCB angioplasty using different inflation time, divided according to whether the total inflation time of the DCB was ≥180 s (prolonged group) or <180 s (standard group). The primary clinical endpoint, defined as a composite of all-cause death, myocardial infarction, stroke, or target lesion revascularization, was examined in 92 propensity score matched pairs.

RESULTS

In the matched cohort, the median clinical follow-up period was 947 days. Postprocedural angiographic diameter stenosis was smaller in the prolonged group than in the standard group (30.0% [22.0-37.0] vs. 33.5% [25.5-40.5]; p = 0.042). Intravascular ultrasound measurements revealed that longer DCB inflation time resulted in smaller area stenosis (66.6 ± 7.8% vs. 69.4 ± 7.0%; p = 0.044) and a less mean increase in percent atheroma volume (-11.2 ± 7.1% vs. -7.4 ± 5.9%; p = 0.004) after angioplasty. The rate of the primary endpoint was lower in the prolonged group than in the standard group (log-rank p = 0.025). The efficacy of prolonged DCB inflation was prominent in patients with in-stent restenosis and longer lesions.

CONCLUSION

Prolonged DCB inflation was associated with reduced residual stenosis and improved clinical outcomes in patients with coronary artery disease undergoing percutaneous coronary intervention. Prospective randomized trials are warranted to validate the benefits of DCB angioplasty with long inflation time.

Для цитирования: Ueda Hiroshi, Fujiwara Yoshihiro, Nishida Yusuke, Maenaka Motoyoshi, Yoshimura Kojiro, Oshida Yuki, Matsuhisa Seiji, Yoshida Naohiro, Yoshitani Hidetoshi, Kuga Yukiko, Ueda Kazuya, Nishida Yasunori. Impact of prolonged drug-coated balloon inflation on residual stenosis and clinical outcomes in coronary artery disease patients: A propensity score matched analysis.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2023. DOI: 10.1002/ccd.30886.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.