DOI 10.1007/s00062-023-01343-6

Медицинская библиотека · Clinical neuroradiology · 2023

Treatment of In-stent Restenosis of the Internal Carotid Artery Using Drug-eluting Balloons.

Marton Annamária, Blényesi Eszter, Török Katalin, Balogh Gábor, Gubucz István, Nardai Sándor, Lenzsér Gábor, Nagy Csaba, Bajzik Gábor, Tollár József, Repa Imre, Nagy Ferenc, Vajda Zsolt

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: In-stent restenosis (ISR) following internal carotid artery (ICA) stenting is relatively common with an estimated incidence of 5%. Treatment options include repeat angioplasty with conventional or drug-eluting balloons (DEB), repeat stent angioplasty and surgical intervention. Application of DEB in ISR of the coronary and peripheral arteries is an established method; however, data on DEB treatment of ICA ISR are sparse. In this work, results from a retrospective cohort of 45 patients harboring 46 ICA ISR lesions treated with DEB angioplasty are presented.

METHODS

Clinical, procedural and imaging data from DEB angioplasty treatment of 46 high-grade ICA ISR lesions in 45 patients, performed between 2013 and 2021 were collected. A single type of DEB (Elutax, Aachen Resonance, Aachen, Germany) was used in all procedures. Imaging follow-up was performed by regular Doppler ultrasound (DUS), verified by computed tomography angiography (CTA) in cases suspicious for a recurrent ISR.

RESULTS

Technical success was 100%. Intraprocedural and postprocedural complications were not encountered. Clinical follow-up was obtained in all patients. Recurrent stroke in the affected territory was not encountered. A recurrent ISR following DEB treatment was confirmed by DUS and CTA in 4/46 (8.7%) of the lesions and were retreated with DEB. A third recurrent ISR occurred in a single case (2%) and following a second DEB retreatment there were no signs of a fourth recurrence after 36 months follow-up.

CONCLUSION

The use of DEB angioplasty is a safe and effective treatment of ICA ISR lesions, yielding significantly better results compared to other modalities. Randomized multicenter studies are warranted.

Для цитирования: Marton Annamária, Blényesi Eszter, Török Katalin, Balogh Gábor, Gubucz István, Nardai Sándor, Lenzsér Gábor, Nagy Csaba, Bajzik Gábor, Tollár József, Repa Imre, Nagy Ferenc, Vajda Zsolt. Treatment of In-stent Restenosis of the Internal Carotid Artery Using Drug-eluting Balloons.. Clinical neuroradiology. 2023. DOI: 10.1007/s00062-023-01343-6.