[Response latency characteristics for ENT medical assessment of auditory brain stem evoked response].
Аннотация
A schematic description of the correlation between the various types of hearing disorders and the behaviour of auditory brain stem responses (ABR) is presented. Conductive pathology and high-frequency cochlear hearing loss prolong wave component latency due to energy loss and hair cell dysfunction. Latency is not affected in flat cochlear hearing loss. Prolonged interwave latencies between wave I and wave V indicate eighth nerve and brain stem disorders. An algorithm in the form of a flow chart was developed for location of the malfunction. Families of characteristics of wave V intensity-latency functions were designed for faster detection and more precise evaluation of conductive and cochlear hearing losses.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.