Jonges G N, Hagen H, Van Noorden C J, Weening R S, Roos D

Аннотация

The sensitivity and specificity of the chromate inhibition test for the determination of glucose-6-phosphate dehydrogenase (G6PD) deficiency in erythrocytes were compared with a cytochemical staining method. Fifty blood samples were used in a double blind study. The samples were selected from 600 blood samples on the basis of two biochemical criteria, viz. either G6PD activity less than 4.8 IU/g Hb as analysed spectrophotometrically and/or G6PD activity less than glutathione reductase (GSSG-R) activity. The cytochemical assay was taken as reference because it has been proved to be sensitive and specific for the detection of heterozygous and homo/hemizygous forms of deficiency. Cytochemically, one hemizygously deficient patient, 19 heterozygotes and 30 normals were detected. When applying the chromate inhibition test a somewhat different result was obtained with the same samples: one of the 30 normals was classified as heterozygously deficient (3% false positives) and 5 of the 19 heterozygously deficient patients were classified as normal (26% false negatives). It is concluded that the chromate inhibition test is a more sensitive biochemical test than the fluorescence spot test or spectrophotometric assays. However, it is less reliable than the cytochemical test for the detection of heterozygously G6PD deficient patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты