MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s002221512100414x

Медицинская библиотека · The Journal of laryngology and otology · 2021

Risk factors for hearing loss in neonates admitted to neonatal intensive care units.

Pan L, Fang X, Chen H, Zhai F, Chen J

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study aimed to research risk factors of hearing loss among neonates in the neonatal intensive care unit.

METHOD: Hearing screening tests were performed on 572 neonates in the neonatal intensive care unit. Those who failed screening tests were referred for diagnostic tests.

RESULTS

The pass rates for automated auditory brainstem response, distortion product otoacoustic emission and acoustic impedance tests at first hearing screening were 69.93 per cent, 70.02 per cent and 92.92 per cent for 1144 ears. Failure in the first screening correlated with preterm birth, very low birth weight, revised advanced maternal age, neonatal hyperbilirubinaemia and Activity, Pulse, Grimace, Appearance, Respiration score less than 8. Thirty cases failed in diagnostic hearing tests for brainstem auditory evoked potentials, 28 failed in otoacoustic emissions and 33 failed in acoustic impedance, which correlated with preterm birth, very low birth weight, twins, advanced maternal age and revised advanced maternal age.

CONCLUSION

Abnormalities in the hearing levels of most neonates who needed hearing retests were completely or partially reversible. Preterm birth, very low birth weight, twins and advanced maternal age are potential risk factors for hearing impairment.

Для цитирования: Pan L, Fang X, Chen H, Zhai F, Chen J. Risk factors for hearing loss in neonates admitted to neonatal intensive care units.. The Journal of laryngology and otology. 2021. DOI: 10.1017/s002221512100414x.