DOI 10.1038/s41598-023-49808-5

Медицинская библиотека · Scientific reports · 2023

A clinical assessment of portable point-of-care testing for quick cortisol assay during adrenal vein sampling.

Aiga Ko, Kometani Mitsuhiro, Karashima Shigehiro, Konishi Seigo, Higashitani Takuya, Aono Daisuke, Mai Xurong, Usukura Mikiya, Asano Takahiro, Wakayama Ayako, Noda Yuko, Koda Wataru, Minami Tetsuya, Kobayashi Satoshi, Murayama Toshinori, Yoneda Takashi

Наблюдательное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

This study assessed the clinical performance of point-of-care testing (POCT) for quick cortisol assay (QCA) during adrenal vein sampling (AVS) using a newly invented portable quantitative assay instrument. An observational study was conducted prospectively at two centres in Japan. Forty-eight patients with primary aldosteronism considered for adrenalectomy were enrolled in this study and underwent AVS. Three basal adrenal vein samples from each adrenal vein and two from the inferior vena cava were collected sequentially. The cortisol concentration of adrenal vein samples was measured by routine method and QCA. A total of 338 adrenal vein samples were analysed from 250 sites to determine AVS success or failure. The distribution of turnaround time of the QCA for AVS success or failure followed a normal distribution with an average of 20.5 min. A positive correlation between the routine method and QCA was observed regarding cortisol concentration or selectivity index. No significant difference between the two methods was observed regarding the success rate of AVS. Using the routine method as a reference, the sensitivity and specificity of AVS success or failure were 99.1% (210/212) and 81.6% (31/38), respectively. Easy, quick, portable, and precise POCT-QCA demonstrated its compatibility with routine methods regarding clinical performance.

Для цитирования: Aiga Ko, Kometani Mitsuhiro, Karashima Shigehiro, Konishi Seigo, Higashitani Takuya, Aono Daisuke, Mai Xurong, Usukura Mikiya, Asano Takahiro, Wakayama Ayako, Noda Yuko, Koda Wataru, Minami Tetsuya, Kobayashi Satoshi, Murayama Toshinori, Yoneda Takashi. A clinical assessment of portable point-of-care testing for quick cortisol assay during adrenal vein sampling.. Scientific reports. 2023. DOI: 10.1038/s41598-023-49808-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.