MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/11297298231213669

Медицинская библиотека · The journal of vascular access · 2023

A modified single-catheter approach for improving adrenal venous sampling in patients with primary aldosteronism.

Wan Jindong, Wang Xinquan, Liu Sen, Hou Jixin, Zhou Peng, Xue Qiang, Wang Peijian

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Adrenal vein sampling (AVS) is an established procedure for assessing subtype patients with primary aldosteronism (PA). However, it is technically challenging, with high failure rates, which limits its application in clinical practice. Our study aimed to evaluate the safety and efficacy of a single-catheter modified approach for AVS.

METHODS

The clinical, angiographic, and procedural data of 182 consecutive patients who underwent AVS procedures between May 2020 and May 2023 were collected and analyzed. The single-catheter modified approach was performed as a single 5 F Tiger catheter with only one-time manual reshaping, which was recommended for sequential bilateral adrenal cannulations.

RESULTS

Of the 182 consecutive patients, 174 (95.6%) had successful bilateral adrenal cannulation. The single-catheter modified approach was successfully performed to cannulate the right adrenal vein in 176 (96.7%) patients, while another six (3.3%) patients needed at least a second manual reshaping for 5 F Tiger catheters. For left adrenal cannulation, a single-catheter modified approach was successfully used in 179 (98.4%) patients, whereas 5 F Tiger catheters with at least second-time manual reshaping were used in the remaining three (1.6%) patients. The procedural period was 15.6 ± 10.8 min, the fluoroscopy time was 4.2 ± 1.5 min, and the diagnostic contrast was 15.5 ± 4.8 mL. The incidence of procedure-related complications associated with AVS was 1.1%. The cumulative summation assessment illustrated that the learning curve for the operating procedure required up to 29 cases, indicating that the procedure time was shortened after 29 cases.

CONCLUSIONS

The single-catheter modified approach is an effective, safe, and feasible technique for AVS treatment. In particular, this improved method is not difficult for beginners with high technical success rates.

Для цитирования: Wan Jindong, Wang Xinquan, Liu Sen, Hou Jixin, Zhou Peng, Xue Qiang, Wang Peijian. A modified single-catheter approach for improving adrenal venous sampling in patients with primary aldosteronism.. The journal of vascular access. 2023. DOI: 10.1177/11297298231213669.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.