MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bmc.1231

Медицинская библиотека · Biomedical chromatography : BMC · 2009

Development and reproducibility of a novel high-performance liquid-chromatography monolithic column method for the detection and quantification of trans-indolyl-3-acryloylglycine in human urine.

Carr Kevin, Whiteley Paul, Shattock Paul

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Elevated levels of trans-indolyl-3-acryloylglycine (IAcrGly) have been reported in the urine of people with various conditions including pervasive developmental disorders (PDDs) such as autism and Asperger syndrome. Reversed-phase high-performance liquid chromatography with ultra-violet detection using traditional particle silica-based columns subsequent to solid-phase extraction (SPE) has been the preferred assay method; requiring long analytical run times, high flow rates and high solvent usage. Recent developments in monolithic HPLC column technology facilitated the development of a novel analytical method, for the detection and quantification of urinary IAcrGly. The revised method eliminates the requirement for SPE pre-treatment, reduces sample run-time and decreases solvent volumes. Five urine samples from people diagnosed with PDD were run in quadruplicate to test the intra- and inter-day reliability of the new method based on retention time, peak area and peak height for IAcrGly. Detection was by UV with IAcrGly confirmation by MS/MS-MS. Relative standard deviations showed significant improvement with the new method for all parameters. The new method represents a major advancement in the detection and quantification of IAcrGly by reducing time and cost of analysis whilst improving detection limits and reproducibility.

Для цитирования: Carr Kevin, Whiteley Paul, Shattock Paul. Development and reproducibility of a novel high-performance liquid-chromatography monolithic column method for the detection and quantification of trans-indolyl-3-acryloylglycine in human urine.. Biomedical chromatography : BMC. 2009. DOI: 10.1002/bmc.1231.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.