MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2022.01.043

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2022

Evaluation of robustly optimised intensity modulated proton therapy for nasopharyngeal carcinoma.

Scandurra Daniel, Meijer Tineke W H, Free Jeffrey, van den Hoek Johanna G M, Kelder Lotta, Oldehinkel Edwin, Steenbakkers Roel J H M, Both Stefan, Langendijk Johannes A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: To evaluate the dosimetric changes occurring over the treatment course for nasopharyngeal carcinoma (NPC) patients treated with robustly optimised intensity modulated proton therapy (IMPT).

MATERIALS AND

METHODS

25 NPC patients were treated to two dose levels (CTV1: 70 Gy, CTV2: 54.25 Gy) with robustly optimised IMPT plans. Robustness evaluation was performed over 28 error scenarios using voxel-wise minimum distributions to assess target coverage and voxel-wise maximum distributions to assess possible hotspots and critical organ doses. Daily CBCT was used for positioning and weekly repeat CTs (rCT) were taken, on which the plan dose was recalculated and robustly evaluated. Deformable image registration was used to warp and accumulate the nominal, voxel-wise minimum and maximum rCT dose distributions. Changes to target coverage, critical organ and normal tissue dose between the accumulated and planned doses were investigated.

RESULTS

2 patients required a plan adaptation due to reduced target coverage. The D98% in the accumulated voxel-wise minimum distribution was higher than planned for CTV1 in 24/25 patients and for CTV2 in 20/25 patients. Maximum doses to the critical organs remained acceptable in all patients. Other normal tissue doses showed some variation as a result of soft tissue deformations and weight change. Normal tissue complication probabilities for grade ≥ 2 dysphagia and grade ≥ 2 xerostomia remained similar to planned values.

CONCLUSION

Robustly optimised IMPT plans, in combination with volumetric verification imaging and adaptive planning, provided robust target coverage and acceptable OAR dose variation in our NPC cohort when accumulated over longitudinal data.

Для цитирования: Scandurra Daniel, Meijer Tineke W H, Free Jeffrey, van den Hoek Johanna G M, Kelder Lotta, Oldehinkel Edwin, Steenbakkers Roel J H M, Both Stefan, Langendijk Johannes A. Evaluation of robustly optimised intensity modulated proton therapy for nasopharyngeal carcinoma.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2022. DOI: 10.1016/j.radonc.2022.01.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.