MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2020.07.092

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2020

Leadless pacemaker implantation under direct visualization during valve surgery.

Shivamurthy Poojita, Miller Marc A, El-Eshmawi Ahmed, Boateng Percy, Pandis Dimosthenis, Pawale Amit, Leviner Dror B, Costa Ana Claudia, Rimsukcharoenchai Chartaroon, Weiner Menachem M, Salter Benjamin, Montgomery Morgan L, Anyanwu Anelechi, Adams David H

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The leadless cardiac pacemaker is typically implanted percutaneously and has been widely used for patients who have already undergone valve surgery. We sought to determine the feasibility and safety of implanting the leadless pacemaker under direct visualization during valve surgery.

METHODS

We performed a retrospective analysis of consecutive adult patients (n = 15) who underwent implantation of a leadless pacemaker under direct visualization at the time of valve surgery. Indications for single-chamber pacing were sick sinus syndrome with pauses (53.3%), atrial fibrillation with slow ventricular rates (13.3%) or complete heart block (6.6%), and elevated risk for postoperative heart block (26.6%). Leadless pacemaker performance and pacing percentage were assessed.

RESULTS

Patients' age was 67.5 ± 17 years, 6 patients (40%) were male, and 14 patients (93%) had atrial fibrillation. Isolated tricuspid valve replacement was performed in 5 patients (33.3%), and the remainder underwent multivalve surgery that included concomitant tricuspid valve repair/replacement. In 93% of the patients (n = 14), the immediate post-cardiopulmonary bypass pacing thresholds were normal (≤2.0 V at 0.24 ms) and normalized in the remaining patient by the next morning. The impedance/sensing values were normal and stable through follow-up (151 ± 119 days) in all patients. Reliable leadless pacemaker performance allowed for deferral of temporary epicardial wires in 11 patients (73%). There were no procedural complications or device malfunction.

CONCLUSIONS

Leadless cardiac pacemaker implantation during valve surgery is feasible and safe. This hybrid approach to pacing may simplify the perioperative management of patients undergoing valve surgery who have an indication for single-chamber pacing.

Для цитирования: Shivamurthy Poojita, Miller Marc A, El-Eshmawi Ahmed, Boateng Percy, Pandis Dimosthenis, Pawale Amit, Leviner Dror B, Costa Ana Claudia, Rimsukcharoenchai Chartaroon, Weiner Menachem M, Salter Benjamin, Montgomery Morgan L, Anyanwu Anelechi, Adams David H. Leadless pacemaker implantation under direct visualization during valve surgery.. The Journal of thoracic and cardiovascular surgery. 2020. DOI: 10.1016/j.jtcvs.2020.07.092.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.