MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40662-025-00440-6

Медицинская библиотека · Eye and vision (London, England) · 2025

Highly efficient stacking ensemble learning model for automated keratoconus screening.

Muhsin Zahra J, Qahwaji Rami, Ghafir Ibrahim, AlShawabkeh Mo'ath, Al Bdour Muawyah, AlRyalat Saif Aldeen, Al-Taee Majid

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Despite extensive research on keratoconus (KC) detection with traditional machine learning models, stacking ensemble learning approaches remain underexplored. This paper presents a stacking ensemble learning method to enhance automated KC screening.

METHODS

This study utilizes a clinical dataset containing detailed corneal data from 2491 cases classified as non-KC (NKC), subclinical KC (SCKC) and clinical KC (CKC). Each cornea is represented by 79 features extracted from Pentacam imaging. Following extensive pre-processing, key corneal features that are strongly correlated with the target diagnosis are identified. These features are the keratometry of the steepest anterior point, surface variance index, vertical asymmetry index, height decentration index, and height asymmetry index. A novel stacking ensemble model is developed using the selected features to improve corneal classification into NKC, SCKC, and CKC by integrating top tree-based classifiers (random forest, gradient boosting, decision trees) with a support vector machine meta-classifier.

RESULTS

The pre-processing and feature selection techniques reduced the model's parameters to just 6.33% of the original dataset, improving classification performance, and cutting over 85% of the training time. The performance of the developed model was validated and tested on unseen data. Experimental results showed that the model outperforms existing studies, achieving 99.72% accuracy, precision, sensitivity, F1, and F2 scores, with a Matthews correlation coefficient of 0.995. It accurately classified all NKC and CKC cases, with just one misclassification involving an SCKC case. The model also demonstrated consistent performance on 100 additional unseen test cases, underscoring its generalizability and robustness in KC screening.

CONCLUSIONS

By combining the strengths of diverse base models and key Pentacam indices, the stacking ensemble approach ensures reliable, accurate KC screening, providing clinicians with an automated tool for early detection and better patient management.

Для цитирования: Muhsin Zahra J, Qahwaji Rami, Ghafir Ibrahim, AlShawabkeh Mo'ath, Al Bdour Muawyah, AlRyalat Saif Aldeen, Al-Taee Majid. Highly efficient stacking ensemble learning model for automated keratoconus screening.. Eye and vision (London, England). 2025. DOI: 10.1186/s40662-025-00440-6.