MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-025-03505-6

Медицинская библиотека · International ophthalmology · 2025

Efficacy of implantable Collamer lens after corneal cross-linking in patients with keratoconus: a systematic review and meta-analysis.

Elgazzar Akram Fekry, Tharwat Ehab, Diab Sherein, Abdella Walid Shaban, Abdelaziz Ahmed, Elejla Sewar, Ahmed Mariam Mohamed, Kamel Mohamed Abdelmonem, Qobeia Esraa, Selim Ahmed Nabil, Abdelhameed Hazem Mohamed, Hassanein Mohamed, Gad Ashraf, El Gabbar Abdel Ghany Ali, Abdelkader Amr Mohammed Elsayed

СтатьяСистематический обзорМетаанализПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the efficacy of implantable Collamer lens (ICL) implantation after corneal collagen cross-linking in keratoconus.

METHODS

We searched PubMed, Cochrane CENTRAL, SCOPUS, Web of Science, and Google Scholar from inception until October 2022. We included the relevant studies that assessed ICL implantation post-corneal collagen cross-linking in patients with keratoconus. The efficacy endpoints were corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), manifest refraction (sphere, cylinder, spherical equivalent), and keratometry.

RESULTS

Seven observational studies were eligible for this systematic review and meta-analysis. ICL implantation showed an improvement in UDVA, 6 months postoperative, with a mean change of - 1.27 log MAR (95% CI [- 1.63 to - 0.9]. However, there was a non-significant improvement in CDVA with a mean change of - 0.04 log MAR (95% CI [- 0.11 to 0.02]. A trend toward the improved sphere and spherical equivalent was observed for all eyes after the ICL implantation approach: mean change of 6.82 diopters (95% CI 3.24 to 10.4) for the sphere and 7.30 diopters (95% CI [4.18 to 10.43]) for the spherical equivalent. The refractive cylinder was not improved after ICL implantation 0.62 diopters (95% CI [- 0.53 to 1.77].

CONCLUSION

The ICL implantation approach appears to be effective for improving visual acuity in patients with keratoconus without adversely affecting corneal keratometry after crosslinking.

Для цитирования: Elgazzar Akram Fekry, Tharwat Ehab, Diab Sherein, Abdella Walid Shaban, Abdelaziz Ahmed, Elejla Sewar, Ahmed Mariam Mohamed, Kamel Mohamed Abdelmonem, Qobeia Esraa, Selim Ahmed Nabil, Abdelhameed Hazem Mohamed, Hassanein Mohamed, Gad Ashraf, El Gabbar Abdel Ghany Ali, Abdelkader Amr Mohammed Elsayed. Efficacy of implantable Collamer lens after corneal cross-linking in patients with keratoconus: a systematic review and meta-analysis.. International ophthalmology. 2025. DOI: 10.1007/s10792-025-03505-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.