MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjophth-2025-002167

Медицинская библиотека · BMJ open ophthalmology · 2025

Bowman's layer and corneal thickness in health and disease.

Shen Yaochun, Zheng Yalin, Borgia Alfredo, Posarelli Matteo, Herbert Rose, Sharp Tom, Pagano Luca, Romano Vito, Madden Andrea, Undan Alexander, Kaye Stephen B

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate central Bowman's layer thickness (BT) in relation to central corneal thickness (CCT) and curvature, and epithelial thickness in healthy and disease corneas.

METHODS

Patients with keratoconus (KC), corneal dystrophies (CD) and healthy controls (HC) were included. Linnik and Mirau versions of an ultra-high axial resolution line field spectral domain optical coherence tomography device were used to image the cornea, in addition to commercially available devices. A supervised automated segmentation process was used to extract the quasi-point thickness of Bowman's layer.

RESULTS

62 participants: 24 with KC, 20 with CD and 18 HC were included. Mean central BT was 15.41 µm (SD 0.49; min-max: 12.28-19.54) in HC, 14.27 µm (SD:0.43; min-max: 11.22-18.25) in KC and 15.65 µm (SD 0.64; min-max: 12.42-20.06) in CD (mainly Fuchs CD). Patients with KC had thinner central BT than those with CD (p=0.03), but not compared with HC (p=0.13). Central BT was significantly associated with CCT (p<0.01), being on average 3% of CCT. The ratio of BT to CCT was independent of diagnosis (CD 0.028, HC 0.030, KC 0.028, p=0.88), age (p=0.23), sex (p=0.67), Kmax (p=0.77) or epithelial thickness (p=0.72).

CONCLUSIONS

Over sample populations of healthy, keratoconic and dystrophic corneas, central BT was consistently associated with corneal thickness and was independent of age, sex, Kmax, and epithelial thickness.

TRIAL REGISTRATION NUMBER: ISRCTN40558.

Для цитирования: Shen Yaochun, Zheng Yalin, Borgia Alfredo, Posarelli Matteo, Herbert Rose, Sharp Tom, Pagano Luca, Romano Vito, Madden Andrea, Undan Alexander, Kaye Stephen B. Bowman's layer and corneal thickness in health and disease.. BMJ open ophthalmology. 2025. DOI: 10.1136/bmjophth-2025-002167.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.