MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-025-03423-7

Медицинская библиотека · International ophthalmology · 2025

Enhancing early detection of keratoconus suspects using interocular corneal tomography asymmetry.

Li Shuangcheng, Huo Yan, Xie Ruisi, Han Yimei, Zou Haohan, Wang Yan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate corneal tomography asymmetry of both eyes in keratoconus (KC), keratoconus suspects (KCS), and normal (NL) eyes, and to introduce an interocular asymmetry index (IAI) for early diagnosis of keratoconus.

METHODS

This prospective case-control study included 210 NL eyes, 140 eyes with KCS, and 40 eyes with KC. New Scheimpflug imaging scans were performed to obtain corneal tomographic parameters. Based on the high and low values of tomographic parameters, each eye was categorized as "worse" or "better." Intragroup correlation coefficients (ICC) were used to compare interocular asymmetry. Logistic regression indices were constructed using interocular differences. Receiver operating characteristic (ROC) curves were used to analyze the sensitivity, specificity, and cutoff values of the IAI.

RESULTS

In the KC group, 86.7% of the parameters significantly differed between the worse and better eyes. In the KCS group, 66.7% of the parameters showed significant differences between the worse and better eyes, with high consistency between the central and thinnest corneal thickness groups (ICC > 0.6). Strong intragroup correlations were observed in the NL group (ICC > 0.6). IAI effectively distinguished the NL from the KCS group (area under the ROC [AUROC] = 0.891), reaching 67.1% sensitivity and 97.1% specificity at a cutoff value of 0.494. At a cutoff value of 0.778, the IAI reached 95.0% sensitivity and 96.2% specificity in distinguishing NL from KC (AUROC = 0.954).

CONCLUSION

Interocular asymmetry in keratoconus suspects can be detected in the early stages, with increased asymmetry compared to NL eyes observed as keratoconus progresses. Interocular asymmetry can complement monocular diagnostic parameters.

Для цитирования: Li Shuangcheng, Huo Yan, Xie Ruisi, Han Yimei, Zou Haohan, Wang Yan. Enhancing early detection of keratoconus suspects using interocular corneal tomography asymmetry.. International ophthalmology. 2025. DOI: 10.1007/s10792-025-03423-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.