Posterior dislocation of descemet stripping automated endothelial keratoplasty graft can lead to retinal detachment.
Клинический случайСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Singh Ajay, Gupta Anurag, Stewart Jay M
Аннотация
PURPOSE: To describe traction retinal detachment as a complication of posterior dislocation of Descemet stripping automated endothelial keratoplasty (DSAEK) graft.
METHODS: Vitrectomy surgery was performed in 3 eyes that developed posterior dislocation of DSAEK graft. Intraoperatively, the corneal tissue was found to be adherent to the retina. In 2 cases, a retinal detachment with proliferative vitreoretinopathy (PVR) was already present and the donor DSAEK flap was found to be fused with the retina. In 1 case, the retina was attached at the time of surgery but PVR subsequently developed despite near total removal of the graft, requiring an additional procedure to achieve retinal reattachment.
RESULTS: Corneal tissue removal with a vitreous cutter was attempted in all cases. Residual tissue that had fused with the retina was left in place. Retinal reattachment was achieved with silicone oil injection in 2 cases and scleral buckle alone in 1 case.
CONCLUSIONS: Posterior segment dislocation of a DSAEK flap and its adherence to the retina may cause PVR and traction retinal detachment. Early removal is warranted when dislocation occurs.
METHODS: Vitrectomy surgery was performed in 3 eyes that developed posterior dislocation of DSAEK graft. Intraoperatively, the corneal tissue was found to be adherent to the retina. In 2 cases, a retinal detachment with proliferative vitreoretinopathy (PVR) was already present and the donor DSAEK flap was found to be fused with the retina. In 1 case, the retina was attached at the time of surgery but PVR subsequently developed despite near total removal of the graft, requiring an additional procedure to achieve retinal reattachment.
RESULTS: Corneal tissue removal with a vitreous cutter was attempted in all cases. Residual tissue that had fused with the retina was left in place. Retinal reattachment was achieved with silicone oil injection in 2 cases and scleral buckle alone in 1 case.
CONCLUSIONS: Posterior segment dislocation of a DSAEK flap and its adherence to the retina may cause PVR and traction retinal detachment. Early removal is warranted when dislocation occurs.