Measurement reproducibility of magnetic resonance imaging-based finite element analysis of proximal femur microarchitecture for in vivo assessment of bone strength.

Chang Gregory, Hotca-Cho Alexandra, Rusinek Henry, Honig Stephen, Mikheev Artem, Egol Kenneth, Regatte Ravinder R, Rajapakse Chamith S

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

INTRODUCTION

Osteoporosis is a disease of weak bone. Our goal was to determine the measurement reproducibility of magnetic resonance assessment of proximal femur strength.

METHODS

This study had institutional review board approval, and written informed consent was obtained from all subjects. We obtained images of proximal femur microarchitecture by scanning 12 subjects three times within 1 week at 3T using a high-resolution 3-D FLASH sequence. We applied finite element analysis to compute proximal femur stiffness and femoral neck elastic modulus.

RESULTS

Within-day and between-day root-mean-square coefficients of variation and intraclass correlation coefficients ranged from 3.5 to 6.6 % and 0.96 to 0.98, respectively.

CONCLUSION

The measurement reproducibility of magnetic resonance assessment of proximal femur strength is suitable for clinical studies of disease progression or treatment response related to osteoporosis bone-strengthening interventions.

Для цитирования: Chang Gregory, Hotca-Cho Alexandra, Rusinek Henry, Honig Stephen, Mikheev Artem, Egol Kenneth, Regatte Ravinder R, Rajapakse Chamith S. Measurement reproducibility of magnetic resonance imaging-based finite element analysis of proximal femur microarchitecture for in vivo assessment of bone strength.. Magma (New York, N.Y.). 2014. DOI: 10.1007/s10334-014-0475-y.