m+Medelevator.RU
← Поиск публикаций
Health and quality of life outcomes · 2014

Translation and validation of the Chinese version of the Quality OF Life Radiation Therapy Instrument and the Head & Neck Module (QOL-RTI/H&N).

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chen Xin-lin, Qiu Zhen-wen, Gu Mo-fa, Su Yong, Liu Li-zhi, Liu Yan, Mo Chuan-wei, Xu Qian, Sun Juan, Li Dong-hai

Аннотация

BACKGROUND: To translate and validate the Chinese version of the Quality Of Life Radiation Therapy Instrument and the Head & Neck Module (QOL-RTI/H&N), a disease-specific scale to measure quality of life (QOL) for patients with head and neck cancer (HNC) who received radiotherapy.

METHODS: The QOL-RTI/H&N was translated and validated according to the standard process: a translation and back-translation procedure, pilot testing and a validation study. HNC patients were enrolled from the Cancer Center of Sun Yat-sen University and assessed using the QOL-RTI/H&N, QLQ-C30 and QLQ-H&N35. Reliability (internal consistency reliability, split-half reliability and test-retest reliability), validity (content validity, construct validity, criterion validity and discriminant validity), and responsiveness analysis were performed to evaluate the psychometric characteristics of the QOL-RTI/H&N.

RESULTS: A total of 238 patients (99.2%) completed the questionnaire. Item RTI23 had 16.0% missing data. Other items had low percentages of missing data (0.4% or 0.8%) or no missing data. The average time to finish the scale was 9.8 minutes. Cronbach's alpha of the domains ranged from 0.41 to 0.77. The split-half reliability coefficients ranged from 0.43 to 0.77. All of the intra-class correlation coefficients were equal to or greater than 0.8. All of the item-own domain correlation coefficients were greater than those of the item-other domain. Confirmatory factor analysis showed that Comparative Fit Index, Normed Fit Index and Non-Normed Fit Index were equal to 1.00. Root Mean Square Error of Approximation was 0.01, with 90% CI (0.00, 0.10). The domain scores of the QOL-RTI/H&N were significantly correlated with those of the QLQ-C30 or QLQ-H&N3. All domain scores of patients in different radiotherapy stages were statistically significant (P < 0.05), apart from the speech domain.

CONCLUSIONS: The Chinese version of the QOL-RTI/H&N is a valid, reliable and responsive scale to measure QOL in HNC patients and can be used to assess the effects of radiotherapy treatment on these patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты