MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Southeast Asian journal of tropical medicine and public health · 2004

Comparison of the diagnostic value of local Widal slide test with imported Widal slide test.

Handojo Indro, Edijanto S P, Probohoesodo M Yolanda, Mahartini Ni Nyoman

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

A laboratory study comparing the Widal slide agglutination test using local antigens produced by Mekar Jaya Diagnostica (SAT-MJD) with imported antigens (Murex, Abbott) was carried out on 55 sera of typhoid fever patients with positive blood culture and 56 sera of non-typhoid febrile patients. The SAT-MJD antigens consisted of a mixture of 5 different phage-types of S. typhi dominantly found in Indonesia. This study revealed the following results: the diagnostic sensitivity of local and imported antigens was 83.93%, the diagnostic specificity of local antigens was higher than the imported antigens ie 82.14% compared with 64.28%, the diagnostic efficiency of local antigens was 82.88% compared with 73.87% of the imported antigens. The diagnostic positive and negative predictive values of the local antigens were 80.70% and 83.63%, respectively. The imported antigen revealed diagnostic positive and negative predictive values of 69.69% and 80%, respectively. The diagnostic specificity and efficiency of local antigens were significantly different (p < 0.02 and p < 0.05) from the imported antigens. The local antigens have some advantages. There was no variation in within-run and between-day test, compared with a 6.6% variation shown by the imported antigen. The test results obtained 5 minutes after mixing the serum with antigens reduced the possibility of false-positive and false-negative results. The cost of local antigens is lower than the imported antigens. Based on these data, the Widal SAT-MJD has a reliable diagnostic value and can be used in small laboratories, such as primary health centers (Puskesmas).

Для цитирования: Handojo Indro, Edijanto S P, Probohoesodo M Yolanda, Mahartini Ni Nyoman. Comparison of the diagnostic value of local Widal slide test with imported Widal slide test.. The Southeast Asian journal of tropical medicine and public health. 2004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.