Медицинская библиотека · Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2022

Diagnostic Accuracy of the Cepheid 3-gene Host Response Fingerstick Blood Test in a Prospective, Multi-site Study: Interim Results.

Sutherland Jayne S, van der Spuy Gian, Gindeh Awa, Thuong Nguyen Thuy Thuong, Namuganga AnnRitah, Owolabi Olumuyiwa, Mayanja-Kizza Harriet, Nsereko Mary, Thwaites Guy, Winter Jill, Dockrell Hazel M, Scriba Thomas J, Geluk Annemieke, Corstjens Paul, Stanley Kim, Richardson Tracy, Shaw Jane A, Smith Bronwyn, Malherbe Stephanus T, Walzl Gerhard, TrENDx-TB Consortium

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

The development of a fast and accurate, non-sputum-based point-of-care triage test for tuberculosis (TB) would have a major impact on combating the TB burden worldwide. A new fingerstick blood test has been developed by Cepheid (the Xpert MTB Host Response [MTB-HR] prototype), which generates a "TB score" based on messenger RNA (mRNA) expression of 3 genes. Here we describe the first prospective findings of the MTB-HR prototype.

METHODS

Fingerstick blood from adults presenting with symptoms compatible with TB in South Africa, The Gambia, Uganda, and Vietnam was analyzed using the Cepheid GeneXpert MTB-HR prototype. Accuracy of the Xpert MTB-HR cartridge was determined in relation to GeneXpert Ultra results and a composite microbiological score (GeneXpert Ultra and liquid culture) with patients classified as having TB or other respiratory diseases (ORD).

RESULTS

When data from all sites (n = 75 TB, 120 ORD) were analyzed, the TB score discriminated between TB and ORD with an area under the curve (AUC) of 0.94 (95% confidence interval [CI], .91-.97), sensitivity of 87% (95% CI, 77-93%) and specificity of 94% (88-97%). When sensitivity was set at 90% for a triage test, specificity was 86% (95% CI, 75-97%). These results were not influenced by human immunodeficiency virus (HIV) status or geographical location. When evaluated against a composite microbiological score (n = 80 TB, 111 ORD), the TB score was able to discriminate between TB and ORD with an AUC of 0.88 (95% CI, .83-.94), 80% sensitivity (95% CI, 76-85%) and 94% specificity (95% CI, 91-96%).

CONCLUSIONS

Our interim data indicate the Cepheid MTB-HR cartridge reaches the minimal target product profile for a point of care triage test for TB using fingerstick blood, regardless of geographic area or HIV infection status.

Для цитирования: Sutherland Jayne S, van der Spuy Gian, Gindeh Awa, Thuong Nguyen Thuy Thuong, Namuganga AnnRitah, Owolabi Olumuyiwa, Mayanja-Kizza Harriet, Nsereko Mary, Thwaites Guy, Winter Jill, Dockrell Hazel M, Scriba Thomas J, Geluk Annemieke, Corstjens Paul, Stanley Kim, Richardson Tracy, Shaw Jane A, Smith Bronwyn, Malherbe Stephanus T, Walzl Gerhard, TrENDx-TB Consortium. Diagnostic Accuracy of the Cepheid 3-gene Host Response Fingerstick Blood Test in a Prospective, Multi-site Study: Interim Results.. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2022. DOI: 10.1093/cid/ciab839.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.