MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina61081322

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2025

Advancing Diagnostics with Semi-Automatic Tear Meniscus Central Area Measurement for Aqueous Deficient Dry Eye Discrimination.

Pena-Verdeal Hugo, Garcia-Queiruga Jacobo, Sabucedo-Villamarin Belen, Garcia-Resua Carlos, Giraldez Maria J, Yebra-Pimentel Eva

СтатьяПеревод пока не подготовлен

Аннотация

Background and

Objectives

To clinically validate a semi-automatic measurement of Tear Meniscus Central Area (TMCA) to differentiate between Non-Aqueous Deficient Dry Eye (Non-ADDE) and Aqueous Deficient Dry Eye (ADDE) patients. Materials and

Methods

120 volunteer participants were included in the study. Following TFOS DEWS II diagnostic criteria, a battery of tests was conducted for dry eye diagnosis: Ocular Surface Disease Index questionnaire, tear film osmolarity, tear film break-up time, and corneal staining. Additionally, lower tear meniscus videos were captured with Tearscope illumination and, separately, with fluorescein using slit-lamp blue light and a yellow filter. Tear meniscus height was measured from Tearscope videos to differentiate Non-ADDE from ADDE participants, while TMCA was obtained from fluorescein videos. Both parameters were analyzed using the open-source software NIH ImageJ.

Results

Receiver Operating Characteristics analysis showed that semi-automatic TMCA evaluation had significant diagnostic capability to differentiate between Non-ADDE and ADDE participants, with an optimal cut-off value to differentiate between the two groups of 54.62 mm2 (Area Under the Curve = 0.714 ± 0.051, p < 0.001; specificity: 71.7%; sensitivity: 68.9%).

Conclusions

The semi-automatic TMCA evaluation showed preliminary valuable results as a diagnostic tool for distinguishing between ADDE and Non-ADDE individuals.

Для цитирования: Pena-Verdeal Hugo, Garcia-Queiruga Jacobo, Sabucedo-Villamarin Belen, Garcia-Resua Carlos, Giraldez Maria J, Yebra-Pimentel Eva. Advancing Diagnostics with Semi-Automatic Tear Meniscus Central Area Measurement for Aqueous Deficient Dry Eye Discrimination.. Medicina (Kaunas, Lithuania). 2025. DOI: 10.3390/medicina61081322.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.