Evaluating the feasibility of intraoral scanning technology for removable partial dentures: ai-assisted measurement analysis and clinical investigation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yang Xinyu, Wu Yumin, Qian Mengke, Wu Ruoyun, Xie Haifeng, Chen Chen
Аннотация
OBJECTIVES: To evaluate the feasibility of intraoral scanning (IOS) for the digital design and fabrication of removable partial dentures (RPDs) across different Kennedy classes, and to compare IOS-based models with conventional final impressions using reverse engineering and artificial intelligence (AI)-assisted analyses. The null hypothesis was that no statistically significant differences exist in 3D deviations between IOS and conventional impression models among Kennedy classes. A secondary hypothesis was that AI-assisted analysis could serve as a reliable supplement to conventional reverse engineering. MATERIALS AND METHODS: Fifty partially edentulous patients underwent two methods. 3D deviations between corresponding maxillary and mandibular models were quantified using reverse engineering software. Subgroup analyses were performed according to Kennedy classification, patient-related factors, and anatomical regions. A PointNet++-based deep learning model was used exclusively for automated segmentation and alignment. Data normality was assessed using Shapiro-Wilk test. One-way or two-way ANOVA with Tukey’s post hoc test was applied. Clinical follow-up was conducted at 3, 6, and 12 months. RESULTS: Smaller deviations were observed in Kennedy Class III and IV cases, whereas larger deviations occurred in Class I and II cases, particularly in soft tissue regions such as the palate, gingival margins, and retromolar pads. Age and sex showed minimal influence, while higher Body Mass Index (BMI) was associated with increased soft tissue deviation. AI-assisted analysis produced results consistent with conventional reverse engineering. CONCLUSIONS: IOS demonstrates stable performance in Kennedy Class III and IV cases and acceptable outcomes in selected Class I and II cases with appropriate clinical adjustment. CLINICAL RELEVANCE: IOS may be applied for RPD fabrication in carefully selected cases; however, free-end extension RPDs still require cautious case selection and post-insertion adjustment.