Assessment of left ventricular systolic function and diastolic time intervals by the bioimpedance polyrheocardiographic system.

Zubarev M, Dumler A, Shutov V, Popov N

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

In order to detect left ventricular systolic function and diastolic time intervals using a new improved bioimpedance polyrheocardiographic system (BPCS), 110 healthy subjects and 128 patients with myocardial infarction were examined. Twenty-four simultaneous measurements of cardiac output by thermodilution and BPCS were performed in 11 patients with complicated acute left ventricular failure. Studies demonstrated a high degree of correlation (r = 0.91, p < 0.001). The correlation between the methods of using signals of the second derivative and the subtracted first derivative waveform of BPCS and continuous-wave Doppler echocardiography of systolic and diastolic time intervals was studies in 51 patients. The methods were closely correlated, especially with respect to left ventricular ejection time (r = 0.95), isovolumic relaxation time (r = 0.85), time to peak filling (r = 0.90), and deceleration of rapid filling time (r = 0.91). New bioimpedance hemodynamic parameters such as peak volume acceleration of ejection (PVAE) and peak power ejection (PPE) in patients with heart failure (NYHA Class I-III) were studied. Significant reductions of PVAE and PPE in groups of patients with marked progression of heart failure were noted. These results have demonstrated that BPCS is a noninvasive, simple accurate method of assessment of left ventricular systolic function and diastolic time intervals.

Для цитирования: Zubarev M, Dumler A, Shutov V, Popov N. Assessment of left ventricular systolic function and diastolic time intervals by the bioimpedance polyrheocardiographic system.. Annals of the New York Academy of Sciences. 1999. DOI: 10.1111/j.1749-6632.1999.tb09467.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.