MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2016.05.085

Медицинская библиотека · The Annals of thoracic surgery · 2016

Morphologic and Functional Markers of Aortopathy in Patients With Bicuspid Aortic Valve Insufficiency Versus Stenosis.

Girdauskas Evaldas, Rouman Mina, Disha Kushtrim, Fey Beatrix, Dubslaff Georg, von Kodolitsch Yskert, Reichenspurner Hermann, Borger Michael A, Kuntze Thomas

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Bicuspid aortic valve (BAV)-associated aortopathy is heterogeneous and still insufficiently defined. We prospectively analyzed the morphologic and functional variables of aortopathy in patients undergoing operations for BAV insufficiency (BAV-AI) vs stenosis (BAV-AS).

METHODS

A total of 172 consecutive patients (71% male, 59 ± 10 years) underwent aortic valve replacement with or without proximal aortic operation for BAV-AS (n = 137), and BAV-AI (n = 35) from January 2012 through December 2014. All patients underwent preoperative cardiac magnetic resonance imaging to evaluate morphologic and functional variables of the aortic root. Magnetic resonance imaging data were used to guide sampling of aortic tissue intraoperatively (ie, from the area where flow jet impacts on the aortic wall [jet sample] and the opposite aortic wall [control sample]). Aortic wall lesions were graded based on the histologic sum score (range, 0 to 21). Expression and severity of aortopathy were quantified by means of proximal aortic phenotype, indexed aortic diameters, and a sum score.

RESULTS

Cross-sectional aortic diameters were significantly larger in the BAV-AI group vs the BAV-AS group (47 ± 8 mm vs 41 ± 8 mm, p = 0.001). Moreover, root dilatation phenotype was more frequent in the BAV-AI group (27% vs 6%, p = 0.01) and was associated with a significantly larger aortic annulus diameter (32 ± 3 mm vs 27 ± 3 mm, p < 0.001). The histologic sum score was significantly different between the study groups (3.7 ± 2.6 BAV-AI vs 2.5 ± 1.4 BAV-AS, p = 0.03). Logistic regression revealed a significant association between BAV-AI and indexed aortic diameter exceeding 22 mm/m2 (odds ratio, 4.7; p = 0.007).

CONCLUSIONS

Our study demonstrates that BAV functional phenotype correlates significantly with the expression and severity of bicuspid aortopathy.

Для цитирования: Girdauskas Evaldas, Rouman Mina, Disha Kushtrim, Fey Beatrix, Dubslaff Georg, von Kodolitsch Yskert, Reichenspurner Hermann, Borger Michael A, Kuntze Thomas. Morphologic and Functional Markers of Aortopathy in Patients With Bicuspid Aortic Valve Insufficiency Versus Stenosis.. The Annals of thoracic surgery. 2016. DOI: 10.1016/j.athoracsur.2016.05.085.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.