MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0165-0327(93)90015-c

Медицинская библиотека · Journal of affective disorders · 1993

ECT in the treatment of the catatonic syndrome.

Rohland B M, Carroll B T, Jacoby R G

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine the efficacy of ECT in the treatment of the catatonic syndrome and to identify predictors of good response.

METHOD: 28 cases of catatonia in 22 patients admitted to a psychiatry or medical psychiatry inpatient unit between January 1989 and June 1992 were retrospectively evaluated. Cases were included if they met criteria for catatonia as described by Kahlbaum, i.e., 4 or more signs including immobility, mutism, withdrawal, staring, rigidity, posturing/gimacing, negativism, waxy flexibility, echo phenomena, stereotypy, and verbigeration. Primary diagnoses were: Major Depressive Disorder (8), Bipolar Affective Disorder (5), schizophrenia (5), schizoaffective disorder (2) and organic mental disorder (2). Mean age was 54.5 years; sex ratio was 15 females to 7 males. Patients received a mean of 12.0 treatments with mean seizure duration 50.9 s (by EEG) per treatment.

RESULTS

By Kahlbaum criteria, resolution of the catatonic syndrome occurred in 26 out of 28 cases (93%). The mean number of signs present per patient prior to ECT was 5.6 versus 0.93 following ECT (p = 0.00001). Overall, ECT brought about resolution of 83.5% of all symptoms with 98% resolution of primary symptoms and 74% resolution of secondary symptoms.

CONCLUSIONS

ECT is an effective treatment of the catatonic syndrome. ECT is effective in the resolution of both cardinal (primary) and secondary signs of catatonia. In this study, there is not a statistically significant difference in the effectiveness of the resolution of catatonic symptoms in persons with affective disorder versus schizophrenia.

Для цитирования: Rohland B M, Carroll B T, Jacoby R G. ECT in the treatment of the catatonic syndrome.. Journal of affective disorders. 1993. DOI: 10.1016/0165-0327(93)90015-c.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.