OBJECTIVE

Respiratory virus testing is routinely performed and ways to obtain specimens aside from a nasopharyngeal swab are needed for pandemic preparedness. The main objective is to validate a self-collected oral-nasal swab for the detection of Influenza and respiratory syncytial virus (RSV).

DESIGN

Diagnostic test validation of a self-collected oral nasal swab as compared to a provider-collected nasopharyngeal swab.

SETTING

Emergency Department at Michael Garron Hospital.

PARTICIPANTS

Consecutive individuals who presented to the Emergency Department with a suspected viral upper respiratory tract infection were included if they self-collected an oral-nasal swab. Individuals testing positive for Influenza or RSV along with randomly selected participants who tested negative were eligible for inclusion.

INTERVENTIONS: All participants had the paired oral-nasal swab tested using a multiplex respiratory virus polymerase chain reaction for the three respiratory pathogens and compared to the nasopharyngeal swab.

RESULTS

48 individuals tested positive for Influenza, severe acute respiratory coronavirus virus 2 (SARS-CoV-2) or RSV along with 80 who tested negative. 110 were symptomatic with the median time from symptom onset to testing of 1 day (interquartile range 2-5 days). Using the clinical nasopharyngeal swab as the reference standard, the sensitivity was 0.75 (95% CI, 0.43-0.95) and specificity was 0.99 (95% CI, 0.93-1.00) for RSV, sensitivity is 0.67 (95% CI, 0.49-0.81) and specificity is 0.96 (95% CI, 0.89-0.99) for Influenza.

CONCLUSIONS

Multiplex testing with a self-collected oral-nasal swab for Influenza and RSV is not an acceptable substitute for a healthcare provider collected nasopharyngeal swab primarily due to suboptimal Influenza test characteristics.

Для цитирования: Young Matthew, Suico Yuri, Vojdani Omid Kyle, McCready Janine, Katz Kevin, Pourmatin Scarlett, Rahimi Manija, Vermeiren Christie, Powis Jeff, Kandel Christopher. Validation of oral-nasal specimen collection for influenza and respiratory syncytial virus detection.. Antimicrobial stewardship & healthcare epidemiology : ASHE. 2025. DOI: 10.1017/ash.2025.66.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.