OBJECTIVES

Cryoglobulins (CGs) are serum proteins that undergo a reverse cold-induced precipitation in vitro. The CGs are a well-known cause of analytical interferences in several laboratory tests, leading to spurious results. With this in view, we present a case of a patient initially misdiagnosed due to CGs interference in Hepatitis C Virus (HCV) serology.

CASE PRESENTATION: We report a case of a woman of advanced age affected by acute renal failure that required urgent haemodialysis. In the absence of infections and other causes of CGs production, a diagnosis of acute renal failure secondary to essential cryoglobulinemia was established. However, an unexpected positive HCV viral load was encountered. At this point, a false-seronegative HCV infection conditioned to CGs interference in vitro was suspected, confirmed by repeating serology in pre-warmed serum. Finally, the patient was correctly diagnosed with HCV-secondary cryoglobulinemia.

CONCLUSIONS

As shown in the case, the presence of CGs in blood may represent a challenge for the correct interpretation of several laboratory tests. The identification of CGs and the pre-treatment of serum are decisive to avoid spurious results and reach a genuine diagnosis.

Для цитирования: Recio Comí Gemma, Molina Clavero Carmen, Calabuig Ballester Sandra, Benavent Bofill Clara, Picó-Plana Ester, Martín Grau Carla, Gutiérrez Fornés Cristina, Sans Mateu Ma Teresa. False-seronegative HCV infection motivated by interference with cryoglobulins.. Advances in laboratory medicine. 2021. DOI: 10.1515/almed-2020-0086.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.