DOI 10.1016/s0030-6657(08)70352-4

Медицинская библиотека · Otolaryngologia polska = The Polish otolaryngology · 2008

[Efferent suppression test--sensitivity and specificity].

Lisowska Grazyna, Namysłowski Grzegorz, Misiołek Maciej, Scierski Wojciech, Orecka Bogusława, Czecior Eugeniusz, Dziendziel Anna

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The amplitude of click evoked otoacoustic emissions can be suppressed (reduced) with contralateral acoustic stimulation (CAS). This is thought to be due to the inhibitory control that the medial efferent auditory nerve exerts on outer hair cell function. One commonly used test of medial olivocochlear (MOC) function in humans involves measuring the degree of suppression of ipsilateral otoacoustic emissions (OAEs) by CAS. This effect is called contralateral suppression, efferent effect or olivocochlear reflex. Aim of the study. The objective of this study was to measure cut-off level of contralateral suppression, sensitivity and specificity of the efferent test.

MATERIAL AND

METHODS

To evaluate the function of MOC system click evoked otoacoustic emissions (CEOAEs) with and without continuous contralateral broadband noise (BBN) stimulation were recorded in 14 patients with multiple sclerosis, 16 patients with unilateral cerebello-pontine angle tumor and control group matched for age and gender. BBN was presented at 50 dB SL and otoacoustic emissions were recorded in response to nonlinear clicks at 70 +/- 3 dB SPL.

RESULTS

The cut-off level was established at -1.4 dB. For 1.4 dB cut-off level of contralateral suppression the sensitivity of the efferent test was 90% and specificity was 70%.

CONCLUSIONS

To conclude, assessment of efferent suppression may be a useful addition to the battery test employed in the investigation of multiple sclerosis and cerebello-pontine angle tumors. The MOC suppression test may provide a tool for an early diagnosis of the brainstem pathology.

Для цитирования: Lisowska Grazyna, Namysłowski Grzegorz, Misiołek Maciej, Scierski Wojciech, Orecka Bogusława, Czecior Eugeniusz, Dziendziel Anna. [Efferent suppression test--sensitivity and specificity].. Otolaryngologia polska = The Polish otolaryngology. 2008. DOI: 10.1016/s0030-6657(08)70352-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.