m+Medelevator.RU
← Поиск публикаций
American journal of ophthalmology · 2014

Prospective head-to-head study comparing 2 commercial interferon gamma release assays for the diagnosis of tuberculous uveitis.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ang Marcus, Wong Wan Ling, Kiew Sieh Yean, Li Xiang, Chee Soon-Phaik

Аннотация

PURPOSE: To perform a head-to-head comparison of 2 commercially available interferon-gamma release assays, QuantiFERON-TB Gold In-Tube (Cellestis, Chadstone, Victoria, Australia) and T-SPOT.TB (Oxford Immunotech, Abingdon, Oxfordshire, UK), in the diagnosis of tuberculous uveitis.

DESIGN: Prospective cohort to study diagnostic accuracy.

METHODS: We recruited consecutive new patients who presented with uveitis to a tertiary institution over a 2-year period. All patients underwent complete ocular examination and systemic evaluation, including T-SPOT.TB, QuantiFERON-TB Gold In-Tube, and tuberculin skin test. Patients were followed-up for a minimum of 1 year after completion of antituberculous therapy where indicated. The main outcome measures were the sensitivity, specificity and accuracy of each test, estimated using Bayesian latent class analysis (presented with 95% Bayesian credible intervals) (Crl). Prior information was obtained from published meta-analyses for diagnostic tests: QuantiFERON Gold In-Tube sensitivity (0.64, 0.59-0.69) and specificity (0.99, 0.99-1.00); T-SPOT. tuberculosis sensitivity (0.50, 0.33-0.67) and specificity (0.91, 0.88-0.93).

RESULTS: From our study in patients with uveitis, QuantiFERON-TB Gold In-Tube was more specific but slightly less sensitive (sensitivity: 0.64, 0.60-0.69; specificity: 0.995, 0.988-0.999) than T-SPOT.TB (sensitivity: 0.67, 0.60-0.74; specificity: 0.91, 0.88-0.93). However, QuantiFERON Gold In-Tube was significantly more accurate in identifying true-positive tuberculous uveitis cases than was T-SPOT.TB among discordant cases (QuantiFERON Gold In-Tube positive 98% vs T-SPOT.TB positive 76%; ratio 1.28, 95% Crl: 1.11-1.72, ie, 95% Crl >1.0, statistically significant).

CONCLUSION: Based on statistical decision theory, our head-to-head study suggests that QuantiFERON-TB Gold In-Tube is the first-line test that should be performed in preference to T-SPOT.TB (and the tuberculin skin test) for diagnosing tuberculous uveitis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты