MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo.2004.061275

Медицинская библиотека · The British journal of ophthalmology · 2005

Systolodiastolic variations of blood flow during central retinal vein occlusion: exploration by dynamic angiography.

Paques M, Baillart O, Genevois O, Gaudric A, Lévy B I, Sahel J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND/AIM: In patients with acute central retinal vein occlusion (CRVO), dynamic angiography may reveal the presence of pulsatile flow (termed here pulsatile venular outflow, PVO) within first order veins (that is, the large veins). The main goal of this study was to investigate the mechanism underlying PVO.

METHODS

10 patients with CRVO and PVO were included. Quantitative and qualitative analysis of venous flow on dynamic angiograms allowed the correlation, temporally, of second and first order vein flow on the one hand, and venous flow and systolic cycle on the other.

RESULTS

Analysis of the time-velocity curve showed that (1) the onset of arterial systole preceded the onset of PVO by less than 0.08 seconds (n = 5); (2) PVO onset was simultaneous to the time of onset of minimal flow (Vmin) in first order veins (n = 10); (3) the time of onset of maximal flow (Vmax) in first order veins occurred 0.20-0.44 seconds after the onset of PVO (n = 6).

CONCLUSIONS

During CRVO with severe reduction in blood flow, the presence of PVO is the result of the existence of a distinct haemodynamic regimen in first and second order veins. These data support the hypothesis that second order veins flow is synchronous with the arterial flow, while the delayed peak flow in first order veins may reflect the consequences of the delayed IOP curve and/or of intermittent venous compression.

Для цитирования: Paques M, Baillart O, Genevois O, Gaudric A, Lévy B I, Sahel J. Systolodiastolic variations of blood flow during central retinal vein occlusion: exploration by dynamic angiography.. The British journal of ophthalmology. 2005. DOI: 10.1136/bjo.2004.061275.