MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsami.4c11393

Медицинская библиотека · ACS applied materials & interfaces · 2024

Multi-Electrode Extended Gate Field Effect Transistors Based on Laser-Induced Graphene for the Detection of Vitamin C and SARS-CoV-2.

Asgharian Heshmat, Kammarchedu Vinay, Soltan Khamsi Pouya, Brustoloni Caroline, Ebrahimi Aida

СтатьяПоддержка правительства СШАПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

Despite the clinical data showing the importance of ascorbic acid (AA or vitamin C) in managing viral respiratory infections, biosensors for their simultaneous detection are lacking. To address this need, we developed a portable and wireless device for simultaneous detection of AA and SARS-CoV-2 virus by integrating commercial transistors with printed laser-induced graphene (LIG) as the extended gate. We studied the effect of laser printing pass number and showed that with two laser printing passes (2-pass LIG), the sensor sensitivity and limit of detection (LOD) for AA improved by a factor of 1.6 and 12.8, respectively. Using complementary characterization methods, we attribute the improved response to a balanced interplay of crystallinity, defect density, surface area, surface roughness, pore density and diameter, and mechanical integrity/stability. These factors enhance analyte transport, reduce noise/variability, and ensure consistent sensor performance, making 2-pass LIG the most effective material in this work. Our sensors exhibit promising performance for detecting AA with a selective response in the presence of common salivary interfering molecules, with sensitivity and LOD of 73.67 mV/dec and 54.04 nM in 1× phosphate buffered saline and 81.05 mV/dec and 78.34 nM in artificial saliva, respectively. We also showed that functionalization of the 2-pass LIG gate with S-protein antibody enables the detection of SARS-CoV-2 protein antigens with an ultralow LOD of 52 zg/mL─an improvement of more than 10-fold compared to 1-pass LIG─and 4 particles/mL for virion mimics with a selective response against influenza virus and multiple human coronavirus strains. With low signal drift/hysteresis and wireless capabilities, the developed device holds great potential for improving at-home monitoring and clinical decision-making.

Для цитирования: Asgharian Heshmat, Kammarchedu Vinay, Soltan Khamsi Pouya, Brustoloni Caroline, Ebrahimi Aida. Multi-Electrode Extended Gate Field Effect Transistors Based on Laser-Induced Graphene for the Detection of Vitamin C and SARS-CoV-2.. ACS applied materials & interfaces. 2024. DOI: 10.1021/acsami.4c11393.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.