DOI 10.3760/cma.j.cn121094-20200512-00253
[Pisussion on noise exposure level measurement and risk assessment of typical posts in coal-fired power plants].
Аннотация
Objective
To study the group noise exposure level of typical coal-fired power plants and explore the establishment of risk assessment methods for noise exposed posts.
Methods
In April 2020, 295 typical workers in 11 coal-fired power plants were selected as the study subjects. The noise exposure dose of typical posts and the proportion of exposure groups under different exposure doses were analyzed, and the risk assessment based on the dose-response relationship was conducted.
Results
The exposure level of typical noise posts in coal-fired power plants was (84.24±4.10) dB (A) , and the over-standard rate was 44.07% (130/295) . The highest noise over-standard rate in main posts were desulfurization inspectors (51.52%) , followed by steam turbine inspectors (47.92%) and belt inspectors (46.32%) . Taking 30 years as an example, the incidence rate of occupational noise deafness of noise-exposed posts in coal-fired power plants was 12.30%. The position with the highest incidence rate was belt inspector (13.21%) , followed by steam turbine inspector (12.97%) , desulfurization inspectors (12.42%) , boiler inspectors (11.59%) and chemical water inspectors (6.89%) .
Conclusion
The risk of noise exposure in coal-fired power plants is relatively high. Comprehensive control measures are recommended to effectively reduce the risk of noise deafness.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.