m+Medelevator.RU
← Поиск публикаций
European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2024

Multicenter comparison of Etest, Vitek2 and BD Phoenix to broth microdilution for beta-lactam susceptibility testing of Streptococcus pneumonia.

СтатьяСравнительное исследованиеМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Martens Steven, Cuypers Lize, Bélik Florian, Briers Pieter-Jan, Ceyssens Pieter-Jan, Denis Olivier, Huang Te-Din, Magerman Koen, Strypens Thomas, Van den Abeele Anne-Marie, Desmet Stefanie, Belgian National Antibiogram Committee

Аннотация

PURPOSE: To assess performance of Etest®, Vitek®2 and BD Phoenix™ to determine the susceptibility of Streptococcus pneumoniae strains to penicillin, ampicillin and cefotaxime.

METHODS: Sixty unique S. pneumoniae challenge strains were selected to cover a wide range of penicillin, ampicillin and cefotaxime minimal inhibitory concentrations (MICs). Strains were analyzed in four different Belgian laboratories. Etest® benzylpenicillin (BEN), ampicillin/amoxicillin (AMP) and cefotaxime (CTA) (bioMérieux), Vitek®2 AST-ST03 (bioMérieux) and BD Phoenix™ SMIC/ID-11 testing were each performed in two different labs. Results were compared to Sensititre® broth microdilution (BMD) (Thermo Fisher Scientific) results. MIC results were interpreted using EUCAST non-meningitis breakpoints (v 13.0).

RESULTS: Essential agreement (EA) was ≥ 90% for all methods compared to BMD, except for Etest® BEN on Oxoid plate (58.3%), Etest® AMP (both on Oxoid (65.8%) and BD BBL plate (84.2%)). Categorical agreement (CA) for penicillin was only ≥ 90% for Vitek®2, for other methods CA ranged between 74 and 84%. CA for AMP was for all methods < 90% (range 75.8-88.3%) and CA for CTA was between 87 and 90% for all methods except for Etest on Oxoid plate (79.2%).

CONCLUSIONS: Our study indicates that Vitek®2 and BD Phoenix™ are reliable for providing accurate pneumococcal susceptibility results for BEN, AMP and CTA. Using Etest BEN or AMP on Oxoid plate carries a risk of underestimating the MIC and should be interpreted with caution, especially when the obtained MIC is 1 or 2 doubling dilutions below the S or R clinical breakpoint.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты