MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.aog.0000109220.24211.bd

Медицинская библиотека · Obstetrics and gynecology · 2004

False-positive 1-hour glucose challenge test and adverse perinatal outcomes.

Stamilio David M, Olsen Tandy, Ratcliffe Sarah, Sehdev Harish M, Macones George A

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine whether a false-positive 1-hour glucose challenge test (GCT) is associated with perinatal complications.

METHODS

We performed a retrospective cohort study of 1825 eligible pregnant women among a cohort of 1998 patients. Patients were screened for gestational diabetes mellitus (GDM) with the 1-hour 50-g GCT at 24-28 gestational weeks. A false-positive GCT was defined as a result greater than or equal to 135 mg/dL followed by a normal 3-hour glucose tolerance test (GTT). We compared the negative GCT and false-positive GCT cohorts for a composite perinatal outcome variable that included fetal macrosomia, antenatal death, shoulder dystocia, chorioamnionitis, preeclampsia, intensive care nursery admission, and postpartum endometritis. Secondary outcomes included cesarean delivery and each component variable of the composite. Unadjusted, stratified, and multiple logistic regression analyses were used to investigate the association between a false-positive GCT and the development of perinatal complications.

RESULTS

We identified 164 patients with a false-positive GCT and 50 patients with GDM. The false-positive GCT cohort on average was older, of higher parity, had a higher body mass index, and more frequently had chronic hypertension, sickle cell trait, and elevated midtrimester human chorionic gonadotropin levels. The false-positive GCT cohort more frequently had adverse perinatal outcomes, including the composite perinatal outcome (odds ratio [OR] 5.96, 95% confidence interval[CI]1.47,24.16), macrosomia greater than 4500 g (OR 3.66, 95% CI 1.30, 10.32), antenatal death (OR 4.61, 95% CI 0.77, 27.48), shoulder dystocia (OR 2.85, 95% CI 1.25, 6.51), endometritis (OR 2.18, 95% CI 1.03, 4.63), and cesarean delivery (OR 1.76, 95% CI 0.99, 3.14).

CONCLUSION

A false-positive GCT is an independent risk factor for adverse perinatal outcomes.

Для цитирования: Stamilio David M, Olsen Tandy, Ratcliffe Sarah, Sehdev Harish M, Macones George A. False-positive 1-hour glucose challenge test and adverse perinatal outcomes.. Obstetrics and gynecology. 2004. DOI: 10.1097/01.aog.0000109220.24211.bd.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.