MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/1475-925x-9-14

Медицинская библиотека · Biomedical engineering online · 2010

A novel method for blood vessel detection from retinal images.

Xu Lili, Luo Shuqian

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The morphological changes of the retinal blood vessels in retinal images are important indicators for diseases like diabetes, hypertension and glaucoma. Thus the accurate segmentation of blood vessel is of diagnostic value.

METHODS

In this paper, we present a novel method to segment retinal blood vessels to overcome the variations in contrast of large and thin vessels. This method uses adaptive local thresholding to produce a binary image then extract large connected components as large vessels. The residual fragments in the binary image including some thin vessel segments (or pixels), are classified by Support Vector Machine (SVM). The tracking growth is applied to the thin vessel segments to form the whole vascular network.

RESULTS

The proposed algorithm is tested on DRIVE database, and the average sensitivity is over 77% while the average accuracy reaches 93.2%.

CONCLUSIONS

In this paper, we distinguish large vessels by adaptive local thresholding for their good contrast. Then identify some thin vessel segments with bad contrast by SVM, which can be lengthened by tracking. This proposed method can avoid heavy computation and manual intervention.

Для цитирования: Xu Lili, Luo Shuqian. A novel method for blood vessel detection from retinal images.. Biomedical engineering online. 2010. DOI: 10.1186/1475-925x-9-14.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.