Comparison of immunochromatographic diagnostic test with Hheminested Reverse transcriptase polymerase chain reaction for detection of rabies virus from brain samples of various species.

Sharma Pranoti, Singh C K, Narang Deepti

СтатьяПеревод пока не подготовлен

Аннотация

AIM: Detection of rabies is a cause of serious concern in developing countries, where dearth of highly equipped laboratories and trained personnel to handle sophisticated investigations is felt. The availability of a diagnostic kit, which can be used in the field, is essential for diagnosis and control programs as well as for epidemiological surveillance of the prevalence of the disease. This study was planned to evaluate anigen rabies Ag test kit for its efficacy to be used for rapid diagnosis of rabies under field conditions. The test results were compared with hemi-nested reverse transcriptase polymerase chain reaction and with a gold standard fluorescent antibody test.

MATERIALS AND

METHODS

A total of 34 brain samples from different rabies suspected animals including dogs, buffaloes, cow, horse, and cat were examined in this study.

RESULTS

Sensitivity of the kit was found to be 91.66%, specificity 100%, and accuracy was 94.11%.

CONCLUSION

The study implies that the immunochromatographic diagnostic test kit may be employed for diagnosis of rabies in field conditions.

Для цитирования: Sharma Pranoti, Singh C K, Narang Deepti. Comparison of immunochromatographic diagnostic test with Hheminested Reverse transcriptase polymerase chain reaction for detection of rabies virus from brain samples of various species.. Veterinary world. 2015. DOI: 10.14202/vetworld.2015.135-138.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.