BACKGROUND

Usually the literature results for device-closure of patent oval foramen concern a single type of device or different devices implanted without anatomical preferences. We propose a strategy of device type and selection based on intra-cardiac echocardiography measurements of inter-atrial septum characteristics.

METHODS

We prospectively enrolled 100 consecutive patients with a mean age of 43 plus or minus 15.5 years, 68 females, who had been referred to our centre for catheter-based closure of inter-atrial shunts over a 48-month period. On the basis of intra-cardiac echocardiography findings the operators selected the Amplatzer Occluder family (AGA Medical Corporation) or the Premere Closure System (St Jude Medical Inc.). Determinants of the selection process were presence and extension of atrial septal aneurysm, tunnel length, rims length, and thickness, presence of additional fenestrations.

RESULTS

According on intra-cardiac echocardiography study, 26 patients have a long channel patent oval foramen, 44 patients had a large atrial septal aneurysm (more than four RL), 24 patients had a moderate atrial septal aneurysm (more than two RL but less than four right-to-left), and six patients had hypertrophic rims. Thus, the Amplatzer PFO Occluder was selected in 24 patients, the Amplatzer ASD Cribriform Occluder in 44 patients, and the Premere device in 32 cases. No aortic erosions, device thrombosis, or recurrent ischaemic cerebral events were observed. Pre-discharge and follow-up occlusion rates were 91% and 96%, respectively.

CONCLUSIONS

Our study suggested that such strategy driven from identification and measurements of the right atrium and inter-atrial septum components resulted in low complications and high-success rates, mandatory conditions when facing with otherwise healthy subjects, such as the patients with patent oval foramen.

Для цитирования: Rigatelli Gianluca, Dell'Avvocata Fabio, Ronco Federico, Giordan Massimo, Cardaioli Paolo. Patent oval foramen transcatheter closure: results of a strategy based on tailoring the device to the specific patient's anatomy.. Cardiology in the young. 2010. DOI: 10.1017/s1047951109990631.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.