Successful treatment of ventricular assist device associated ventricular thrombus with systemic tenecteplase.

Hayes H, Dembo L, Larbalestier R, O'Driscoll G

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

We report a case of intracardiac thrombus in a patient supported by the Jarvik 2000 Flowmaker successfully treated with a single dose of peripherally administered TNK-tissue plasminogen activator (Tenecteplase, Metalyse, Boehringer Ingelheim). This strategy may be considered in the case of life-threatening VAD associated thrombosis to avoid the need for intracardiac drug delivery or VAD replacement. We also discuss the apparent increased thrombotic risk in patients receiving a VAD for chemotherapy induced cardiomyopathy and the implications this may have for the choice of VAD.

Для цитирования: Hayes H, Dembo L, Larbalestier R, O'Driscoll G. Successful treatment of ventricular assist device associated ventricular thrombus with systemic tenecteplase.. Heart, lung & circulation. 2007. DOI: 10.1016/j.hlc.2007.04.012.