BACKGROUND

The detection and differentiation of intracardiac masses is still challenging and may include neoplasms and thrombi. The aim of this study was the investigation of a targeted, fibrin-specific contrast agent (EP-2104R) for molecular targeted magnetic resonance imaging (MRI) of left atrial clots.

METHODS AND

RESULTS

Chronic human thrombi were surgically implanted in the left atrial appendage of 5 swine. Molecular MRI was performed with a navigator-gated, free-breathing, cardiac-triggered 3D inversion-recovery, black-blood, gradient-echo sequence before and after systemic administration of 4 micromol/kg EP-2104R. MR images were analyzed by 2 investigators, and the contrast-to-noise ratio was calculated. Location of clots was confirmed by autopsy, and the gadolinium concentration in the clots was assessed. Before contrast agent administration, thrombi were not visible on black-blood MR images. After contrast administration, all atrial clots (n=5) were selectively visualized as white spots with a high contrast-to-noise ratio (clot/blood, 29.7+/-8.0). The gadolinium concentration in the clots averaged 74+/-45 micromol/L.

CONCLUSIONS

The fibrin-specific MR contrast agent EP-2104R allows for selective and high-contrast visualization of left atrial clots by means of molecular targeted MRI.

Для цитирования: Spuentrup Elmar, Fausten Bernd, Kinzel Sylvia, Wiethoff Andrea J, Botnar Rene M, Graham Philip B, Haller Stephan, Katoh Marcus, Parsons Edward C, Manning Warren J, Busch Thomas, Günther Rolf W, Buecker Arno. Molecular magnetic resonance imaging of atrial clots in a swine model.. Circulation. 2005. DOI: 10.1161/circulationaha.104.529941.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.