m+Medelevator.RU
← Поиск публикаций
Plastic and reconstructive surgery · 2006

Reconstruction of internal orbital wall fracture with iliac crest free bone graft: clinical, computed tomography, and magnetic resonance imaging follow-up study.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kontio Risto K, Laine Pekka, Salo Antero, Paukku Pertti, Lindqvist Christian, Suuronen Riitta

Аннотация

BACKGROUND: The purpose of this study was to clinically and radiologically assess the outcome of internal orbital reconstruction with an iliac bone graft.

METHODS: Twenty-four consecutive patients with unilateral orbital wall fractures were enrolled in this prospective study. A medial cortical wall from the anterior ilium was used for reconstruction. At each follow-up visit, globe posture, diplopia, and eye movements were assessed. Coronal and sagittal computed tomography and magnetic resonance imaging were used to observe graft posture, bone defects, and intraorbital soft-tissue changes.

RESULTS: Most fractures (46 percent) were pure orbital floor fractures. The mean follow-up was 7.8 months. One patient with medial wall and floor fractures required reoperation because of insufficient bone graft. At the last follow-up, this was the only patient (4 percent) with both enophthalmos (2 mm) and hypophthalmos (3 mm). Five patients (21 percent) had hypophthalmos (> 1 mm) at the end of the study. Resorption and remodeling were detected in all grafts, but no grafts were totally resorbed. Sagittal or coronal bone graft postures were assessed as good in 18 orbits (75 percent). Bone defects (> 10 mm) at reconstructed areas were detected in 13 orbits (54 percent). Scar tissue was observed only in three reconstructed orbits (13 percent). Diplopia in central field of vision was registered in seven patients preoperatively but in none at the end of the study.

CONCLUSIONS: The resorption rate was high, but most of it was advantageous remodeling. Overall outcome was good. Secondary operations led to poor outcomes. Thin computed tomography and magnetic resonance imaging sections (< or = 2 mm) are needed to evaluate accurately bone graft placement and posture and orbital volume.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты