MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5935/0004-2749.2024-0170

Медицинская библиотека · Arquivos brasileiros de oftalmologia · 2025

Retinopathy of prematurity: Accuracy of ROPScore and WINROP algorithms in a Brazilian population.

Morais Amanda F L, Hopker Luisa M, Moraes Nilva S B, Reichert Bernardo, Prá Murilo V De, Linhares Anna Carolina B, Takashima Ricardo M, Allemann Norma

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the sensitivity and specificity of the retinopathy of prematurity score (ROPScore) and weight, insulin-like growth factor-1, retinopathy of prematurity algorithm in predicting the risk of developing severe retinopathy of prematurity (prethreshold type 1) in a sample of preterm infants in Brazil.

METHODS

Retrospective analysis of medical records of preterm infants (n=288) with birth weight of ≤1500 g and/or gestational age of 23-32 weeks in a neonatal unit in Southern Brazil from May 2013 to December 2020 (92 months).

RESULTS

The incidence of confirmed severe retinopathy of prematurity was 6.6%. ROPScore showed a 100% sensitivity, 44.6% specificity (95% confidence interval [CI] 38.7-50.6), 11.3% positive predictive value (95% CI 6.5-16.1), and 100% negative predictive value in predicting severe retinopathy of prematurity. The weight, insulin-like growth factor-1, retinopathy of prematurity algorithm demonstrated a 78.9% sensitivity (95% CI 60.6-97.3), 51.3% specificity (95% CI 45.3-57.3), 10.3% positive predictive value (95% CI 5.3-15.2), and 97.2% negative predictive value (95% CI 94.5-99.9).

CONCLUSION

ROPScore identified all patients at risk for severe retinopathy of prematurity. These findings support incorporating ROPScore into Brazilian guidelines to optimize retinopathy of prematurity screening and reduce unnecessary ophthalmologic examinations. Weight, insulin-like growth factor-1, retinopathy of prematurity's suboptimal performance in this Brazilian sample highlights the need for country-specific algorithm adjustments.

Для цитирования: Morais Amanda F L, Hopker Luisa M, Moraes Nilva S B, Reichert Bernardo, Prá Murilo V De, Linhares Anna Carolina B, Takashima Ricardo M, Allemann Norma. Retinopathy of prematurity: Accuracy of ROPScore and WINROP algorithms in a Brazilian population.. Arquivos brasileiros de oftalmologia. 2025. DOI: 10.5935/0004-2749.2024-0170.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.