MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jviromet.2013.06.031

Медицинская библиотека · Journal of virological methods · 2013

Cycling probe technology to quantify and discriminate between wild-type varicella-zoster virus and Oka vaccine strains.

Ihira Masaru, Higashimoto Yuki, Kawamura Yoshiki, Sugata Ken, Ohashi Masahiro, Asano Yoshizo, Yoshikawa Tetsushi

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Rapid differentiation between wild-type varicella zoster virus (VZV) and Oka-vaccine (vOka) strains is important for monitoring side reactions of varicella vaccination. To develop a high-throughput molecular diagnostic method for the differentiation of wild-type VZV and vOka strains based on cycling probe technology. The primers were designed to amplify common sequences spanning a single nucleotide polymorphism (SNP) in gene 62 of VZV. DNA-RNA chimeric probes (cycling probes) were designed to detect the SNP at nucleotide 105705. The cycling probe real-time PCR assays for VZV wild-type and vOka strains specifically amplified plasmids containing target sequences that ranged between 10 and 1×10(6) copies per reaction. The inter- and intra-assay coefficients of variation were less than 5%. After initial validation studies, the clinical reliability of this method was evaluated using 38 swab samples that were collected from patients suspected of being zoster. Compared to the loop mediated isothermal amplification method, which is defined as the gold standard, cycling probe real-time PCR was highly sensitive and specific. The cycling probe real-time PCR technology is a reliable tool for differentiating between wild-type VZV and vOka strains in clinical samples.

Для цитирования: Ihira Masaru, Higashimoto Yuki, Kawamura Yoshiki, Sugata Ken, Ohashi Masahiro, Asano Yoshizo, Yoshikawa Tetsushi. Cycling probe technology to quantify and discriminate between wild-type varicella-zoster virus and Oka vaccine strains.. Journal of virological methods. 2013. DOI: 10.1016/j.jviromet.2013.06.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.