Soft Optical Sensor for Embryo Quality Evaluation Based on Multi-Focal Image Fusion and RAG-Enhanced Vision Transformers.

Jonaitis Domas, Raudonis Vidas, Drejeriene Egle, Kozlovskaja-Gumbriene Agne, Salumets Andres

СтатьяПеревод пока не подготовлен

Аннотация

Assessing human embryo quality is a critical step in in vitro fertilization (IVF), yet traditional manual grading remains subjective and physically limited by the shallow depth-of-field in conventional microscopy. This study develops a novel "soft optical sensor" architecture that transforms standard optical microscopy into an automated, high-precision instrument for embryo quality assessment. The proposed system integrates two key computational innovations: (1) a multi-focal image fusion module that reconstructs lost morphological details from Z-stack focal planes, effectively creating a 3D-aware representation from 2D inputs; and (2) a retrieval-augmented generation (RAG) framework coupled with a Swin Transformer to provide both high-accuracy classification and explainable clinical rationales. Validated on a large-scale clinical dataset of 102,308 images (prior to augmentation), the system achieves a diagnostic accuracy of 94.11%. This performance surpasses standard single-plane analysis methods by 9.43%, demonstrating the critical importance of fusing multi-focal data. Furthermore, the RAG module successfully grounds model predictions in standard ESHRE consensus guidelines, generating natural language explanations. The results demonstrate that this soft sensor approach significantly reduces inter-observer variability and offers a robust tool for standardized morphological assessment, though prospective validation against live birth outcomes remains essential for clinical adoption.

Для цитирования: Jonaitis Domas, Raudonis Vidas, Drejeriene Egle, Kozlovskaja-Gumbriene Agne, Salumets Andres. Soft Optical Sensor for Embryo Quality Evaluation Based on Multi-Focal Image Fusion and RAG-Enhanced Vision Transformers.. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26051441.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.