MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina59030445

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2023

Extracorporeal Circulation and Optic Nerve Ultrasound: A Pilot Study.

Taşkın Öztürk, Demir Ufuk

СтатьяПеревод пока не подготовлен

Аннотация

Background and

Objectives

Cardiopulmonary bypass (CPB) is an extracorporeal circuit that provides surgical access to an immobile and bloodless area, allowing for technical and procedural advances in cardiothoracic surgery. CBP can alter the integrity of the blood-brain barrier and cause changes in intracranial pressure (ICP) postoperatively. Optical nerve sheath diameter (ONSD) measurement is among the alternative non-invasive methods for ICP monitoring. In this study, we aimed to evaluate the optic nerve sheath diameter measurements under the guidance of ultrasonography for ICP changes during the extracorporeal circulation process. Materials and

Methods

The study population included 21 patients over 18 years of age who required extracorporeal circulation. Demographic data of the patients, such as age, gender, comorbidity, American Society of Anesthesiologists (ASA) classification and reason for operation (coronary artery disease or mitral or aortic valve disease) were recorded. The ONSD was measured and evaluated before the extracorporeal circulation (first time) and at the 30th minute (second time), 60th minute (third time) and 90th minute (fourth time) of the extracorporeal circulation. Non-invasive ICP (ICP ONSD) values were calculated based on the ONSD values found.

Results

The mean ONSD values measured before the extracorporeal circulation of the patients were found to be 4.13 mm (3.8-4.6) for the right eye and 4.36 mm (4.1-4.7) for the left eye. Calculated nICPONSD values of 11.0 mm Hg (1.0-21.0) for the right eye and 10.89 mm Hg (1.0-21.0) for the left eye were found. It was observed that there was a significant increase in the ONSD and nlCPONSD values recorded during the extracorporeal circulation of all patients compared to the baseline values (p < 0.005).

Conclusions

During extracorporeal circulation, ultrasound-guided ONSD measurement is an easy, inexpensive and low-complication method that can be performed at the bedside during the operation to monitor ICP changes.

Для цитирования: Taşkın Öztürk, Demir Ufuk. Extracorporeal Circulation and Optic Nerve Ultrasound: A Pilot Study.. Medicina (Kaunas, Lithuania). 2023. DOI: 10.3390/medicina59030445.