The Journal of thoracic and cardiovascular surgery · 2022
Redefining "low risk": Outcomes of surgical aortic valve replacement in low-risk patients in the transcatheter aortic valve replacement era.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Johnston Douglas R, Mahboubi Rashed, Soltesz Edward G, Artis Amanda S, Roselli Eric E, Blackstone Eugene H, Svensson Lars G, Cleveland Clinic Aortic Valve Center Collaborators
Аннотация
OBJECTIVES: Guidelines suggest aortic valve replacement (AVR) for low-risk asymptomatic patients. Indications for transcatheter AVR now include low-risk patients, making it imperative to understand state-of-the-art surgical AVR (SAVR) in this population. Therefore, we compared SAVR outcomes in low-risk patients with those expected from Society of Thoracic Surgeons (STS) models and assessed their intermediate-term survival.
METHODS: From January 2005 to January 2017, 3493 isolated SAVRs were performed in 3474 patients with STS predicted risk of mortality <4%. Observed operative mortality and composite major morbidity or mortality were compared with STS-expected outcomes according to calendar year of surgery. Logistic regression analysis was used to identify risk factors for these outcomes. Patients were followed for time-related mortality.
RESULTS: With 15 observed operative deaths (0.43%) compared with 55 expected (1.6%), the observed:expected ratio was 0.27 for mortality (95% confidence interval [CI], 0.14-0.42), stroke 0.65 (95% CI, 0.41-0.89), and reoperation 0.50 (95% CI, 0.42-0.60). Major morbidity or mortality steadily declined, with probabilities of 8.6%, 6.7%, and 5.2% in 2006, 2011, and 2016, respectively, while STS-expected risk remained at approximately 12%. Mitral valve regurgitation, ventricular hypertrophy, pulmonary, renal, and hepatic failure, coronary artery disease, and earlier surgery date were residual risk factors. Survival was 98%, 91%, and 82% at 1, 5, and 9 years, respectively, superior to that predicted for the US age-race-sex-matched population.
CONCLUSIONS: STS risk models overestimate contemporary SAVR risk at a high-volume center, supporting efforts to create a more agile quality assessment program. SAVR in low-risk patients provides durable survival benefit, supporting early surgery and providing a benchmark for transcatheter AVR.
METHODS: From January 2005 to January 2017, 3493 isolated SAVRs were performed in 3474 patients with STS predicted risk of mortality <4%. Observed operative mortality and composite major morbidity or mortality were compared with STS-expected outcomes according to calendar year of surgery. Logistic regression analysis was used to identify risk factors for these outcomes. Patients were followed for time-related mortality.
RESULTS: With 15 observed operative deaths (0.43%) compared with 55 expected (1.6%), the observed:expected ratio was 0.27 for mortality (95% confidence interval [CI], 0.14-0.42), stroke 0.65 (95% CI, 0.41-0.89), and reoperation 0.50 (95% CI, 0.42-0.60). Major morbidity or mortality steadily declined, with probabilities of 8.6%, 6.7%, and 5.2% in 2006, 2011, and 2016, respectively, while STS-expected risk remained at approximately 12%. Mitral valve regurgitation, ventricular hypertrophy, pulmonary, renal, and hepatic failure, coronary artery disease, and earlier surgery date were residual risk factors. Survival was 98%, 91%, and 82% at 1, 5, and 9 years, respectively, superior to that predicted for the US age-race-sex-matched population.
CONCLUSIONS: STS risk models overestimate contemporary SAVR risk at a high-volume center, supporting efforts to create a more agile quality assessment program. SAVR in low-risk patients provides durable survival benefit, supporting early surgery and providing a benchmark for transcatheter AVR.