Metal-on-Metal Hip Joint Prostheses: a Retrospective Case Series Investigating the Association of Systemic Toxicity with Serum Cobalt and Chromium Concentrations.
Аннотация
INTRODUCTION
There have been concerns about prosthesis failure and the potential for systemic toxicity due to release of cobalt and chromium from metal-on-metal hip joint prostheses (MoM-HP). There is conflicting evidence on whether there is a correlation between higher cobalt and chromium concentrations and systemic toxicity.
METHODS
We undertook a retrospective review of consecutive patients with MoM-HP referred for outpatient review in toxicology clinics in London, UK, and in the USA recorded in the Toxicology Investigators Consortium (ToxIC) Registry from June 2011 to June 2015.
RESULTS
Thirty-one cases were identified; the median (IQR) serum cobalt concentration was 10.0 (3.8-32.8) mcg/L, and the median (IQR) serum chromium concentration was 6.9 (3.7-18.7) mcg/L. Twenty-three (74.2%) had symptoms, most commonly lethargy, hearing loss, and tinnitus. The odds ratios of symptomatic/asymptomatic patients for metal ion concentrations above/below 7 mcg/L were 1.87 (95% CI 0.37-9.57, p = 0.45) and 0.60 (95% CI 0.10-3.50, p = 0.57) for cobalt and chromium, respectively. Two (6.5%) patients with systemic cobalt toxicity had median (IQR) serum cobalt concentrations significantly higher than those without systemic features (630.4 [397.6-863.2] mcg/L versus 9.8 [2.9-16.4] mcg/L; p = 0.017). However, overall, there were no differences between cobalt (p = 0.38) or chromium (p = 0.92) concentrations between symptomatic and asymptomatic patients and no clinical features or investigation results correlated with cobalt or chromium concentration.
CONCLUSION
Two (6.5%) of 31 individuals referred for assessment of MoM-HP were diagnosed with systemic cobalt toxicity. However, despite a high prevalence of reported symptoms, neither symptoms nor investigation results correlated with serum cobalt or chromium concentrations.