Patient-specific modeling of radiation-induced lymphopenia for head and neck cancer.

Li Jiaxin, Mali Rahul, Gan Gregory N, Lominska Christopher, Guida Kenny, Juloori Aditya, Chen Matthew Wen-Ruey, Li Wangyao, Setianegara Jufri, Wang Chao, Lin Yuting, Li Qiang, Chen Weiqiang, Gao Hao

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Radiation-induced lymphopenia (RIL) is a frequent complication in head and neck cancer (HNC) patients undergoing radiotherapy (RT), and its severity is associated with poorer survival outcomes.

PURPOSE: This work aims to develop a patient-specific modeling method to simulate lymphocyte kinetics during and after RT and evaluate the lymphocyte-sparing effects across different RT treatment regimens.

METHODS

A cohort of 17 HNC patients receiving unilateral irradiation with protons or photons were included in this study. The dose to circulating lymphocytes was calculated using the HEDOS model, considering lymph nodes on the irradiated side, the esophagus, auto-segmented bilateral carotid arteries and jugular veins, skeletal muscle, fat, skin, compact bone, spongy bone, red marrow, and other skeleton. A patient-specific model was developed to simulate lymphocyte kinetics that account for radiation-induced damage to both circulating lymphocytes and lymph nodes. The weekly absolute lymphocyte counts (ALC) before, during and after RT, were assembled to estimate the patient-specific parameters. Four different RT treatment regimens-conventional fractionation, hypofractionation, stereotactic body radiotherapy (SBRT), and FLASH-were evaluated to compare their lymphocyte-sparing effects.

RESULTS

Patients treated with protons had 17.1% less grade 3 and 4 RIL compared to photons. The mean dose to circulating lymphocytes was 1.28 ± 0.37 Gy(RBE) for proton therapy and 3.12 ± 0.75 Gy for photon therapy. The patient-specific model captured three distinct patterns of ALC kinetics: plateau phase, normal recovery, and incomplete recovery, with a mean squared error (MSE) of 0.024 ± 0.025 (mean ± SD) between the simulated and observed ALC values. On average, 42.72% of circulating lymphocytes received more than 0.1 Gy(RBE) in proton FLASH, significantly less than the 81.94% in photon FLASH. Hypofractionated RT, SBRT, and FLASH were 6.5%, 20.2%, and 29.9%, respectively, higher than conventional RT in term of ALC levels 3 months post-RT. At 1 year post-RT, most patients achieved at least 70% recovery of baseline ALC for all treatment regimens.

CONCLUSION

A patient-specific method has been developed for modeling lymphocyte dynamics over the course of RT and the subsequent follow-up period for HNC patients.

Для цитирования: Li Jiaxin, Mali Rahul, Gan Gregory N, Lominska Christopher, Guida Kenny, Juloori Aditya, Chen Matthew Wen-Ruey, Li Wangyao, Setianegara Jufri, Wang Chao, Lin Yuting, Li Qiang, Chen Weiqiang, Gao Hao. Patient-specific modeling of radiation-induced lymphopenia for head and neck cancer.. Medical physics. 2025. DOI: 10.1002/mp.17829.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.