MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.18-23954

Медицинская библиотека · Investigative ophthalmology & visual science · 2018

Orientation Tuning and Contrast Dependence of Continuous Flash Suppression in Amblyopia and Normal Vision.

Gao Tina Y, Ledgeway Timothy, Lie Alyssa L, Anstice Nicola, Black Joanna, McGraw Paul V, Thompson Benjamin

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Suppression in amblyopia may be an unequal form of normal interocular suppression or a distinct pathophysiology. To explore this issue, we examined the orientation tuning and contrast dependence of continuous flash suppression (CFS) in adults with amblyopia and visually normal controls.

METHODS

Nine patients (mean age, 26.9 ± SD 4.7 years) and 11 controls (mean age, 24.8 ± SD 5.3 years) participated. In the CFS paradigm, spatially one-dimensional noise refreshing at 10 Hz was displayed in one eye to induce suppression of the other eye, and suppression strength was measured by using a grating contrast increment detection task. In experiment 1, noise contrast was fixed and the orientation difference between the noise and the grating was varied. In experiment 2, noise and grating orientations were identical and noise contrast was varied.

RESULTS

Suppression patterns varied in both groups. In experiment 1, controls showed consistently orientation-tuned CFS (mean half-height bandwidth, 35.8° ± SD 21.5°) with near-equal strength between eyes. Five of nine patients with amblyopia exhibited orientation-independent CFS. Eight patients had markedly unequal suppression between eyes. Experiment 2 found that increasing the noise contrast to the amblyopic eye may produce suppression of the fellow eye, but suppression remained unequal between eyes.

CONCLUSIONS

Our data revealed that orientation specificity in CFS was very broad or absent in some patients with amblyopia, which could not be predicted by clinical measures. Suppression was unbalanced across the entire contrast range for most patients. This suggests that abnormal early visual experience disrupts the development of interocular suppression mechanisms.

Для цитирования: Gao Tina Y, Ledgeway Timothy, Lie Alyssa L, Anstice Nicola, Black Joanna, McGraw Paul V, Thompson Benjamin. Orientation Tuning and Contrast Dependence of Continuous Flash Suppression in Amblyopia and Normal Vision.. Investigative ophthalmology & visual science. 2018. DOI: 10.1167/iovs.18-23954.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.