Arnold Robert W, O'Neil James W, Cooper Kim L, Silbert David I, Donahue Sean P
Аннотация
PURPOSE: To determine the specificity and sensitivity of a smartphone app (GoCheckKids [GCK] used as a photoscreening tool on the iPhone 7 to detect refractive amblyopia risk factors in children aged 1-6 years.
PARTICIPANTS AND METHODS: A prospective, multicenter, 10-month evaluation of children aged 1-6 years old who underwent photoscreening with the GCK app to detect amblyopia risk factors. The first acceptable quality photograph of each study subject was evaluated by trained technicians using GCK's proprietary automated image processing algorithm to analyze for amblyopia risk factors. Trained graders, masked to the cycloplegic clinical data, remotely reviewed photographs taken with the app and compared results to the gold standard pediatric ophthalmology examinations using the 2013 American Association for Pediatric Ophthalmology & Strabismus amblyopia risk factor guidelines. Primary outcome was the ability of the GCK app to identify amblyopia risk factors compared to the cycloplegic refraction.
RESULTS: There were 287 patient images analyzed. The overall sensitivity and specificity in detecting amblyopia risk factors were 76% and 85%, respectively using manual grading. The overall automated grading results had a sensitivity and sensitivity in detecting amblyopia risk factors of 65% and 83%, respectively.
CONCLUSION: The GCK smartphone app is a viable photoscreening device for the detection of amblyopia risk factors in children aged 1-6 years.
PARTICIPANTS AND METHODS: A prospective, multicenter, 10-month evaluation of children aged 1-6 years old who underwent photoscreening with the GCK app to detect amblyopia risk factors. The first acceptable quality photograph of each study subject was evaluated by trained technicians using GCK's proprietary automated image processing algorithm to analyze for amblyopia risk factors. Trained graders, masked to the cycloplegic clinical data, remotely reviewed photographs taken with the app and compared results to the gold standard pediatric ophthalmology examinations using the 2013 American Association for Pediatric Ophthalmology & Strabismus amblyopia risk factor guidelines. Primary outcome was the ability of the GCK app to identify amblyopia risk factors compared to the cycloplegic refraction.
RESULTS: There were 287 patient images analyzed. The overall sensitivity and specificity in detecting amblyopia risk factors were 76% and 85%, respectively using manual grading. The overall automated grading results had a sensitivity and sensitivity in detecting amblyopia risk factors of 65% and 83%, respectively.