BACKGROUND

Insulin resistance (IR) was reported in most polycystic ovarian syndrome (PCOS) cases. Metformin, a biguanide drug, successfully reduced IR. Homeostatic Model Assessment for IR (HOMA-IR) and Doppler parameters assessed metformin's effectiveness.

AIM: To verify whether the area under the curve of the internal carotid artery (AUC-ICA) Doppler wave can be a useful marker for assessing IR among PCOS cases who presented with menstrual irregularity and were treated with metformin over 6 mo.

METHODS

An observational, cross-sectional study recruited 54 eligible PCOS women; the anthropometrics were as follows: age, body mass index (BMI), menstrual cycle days, biochemical serum cholesterol, low and high-density lipoprotein, sex hormone-binding globulin, fasting blood glucose, and HOMA-IR, hormonal testosterone, luteinizing hormone over follicle-stimulating hormone ratio, and ultrasonic pulsatility index (PI) and resistance index (RI), carotid artery intima-media thickness (CIMT) and (AUC-ICA) parameters were initially recorded and repeated 3 mo and 6 mo later with metformin tab 500 mg; three times/day for 6 mo. In addition, AUC-ICA was assessed by taking repeated systolic and diastolic wave height measurements.

RESULTS

Metformin caused a progressive reduction in BMI, menstrual cycle days, biochemical hormonal, and Doppler parameters (CIMT, PI, RI, and AUC-ICA). AUC-ICA correlated strongly to all PCOS parameters. AUC-ICA correlated inversely with treatment time (r = -0.98, P < 0.001) and positively with HOMA-IR (r = 0.98, P < 0.0001). Via the best subset regression model, the AUC-ICA had the highest predictive value for HOMA-IR.

CONCLUSION

AUC-ICA preceded PI, RI, and CIMT with a strong, meaningful correlation to all PCOS parameters, making it a reliable marker for the assessment of IR, especially during metformin therapy. Further studies are recommended to promote the application in practice.

Для цитирования: Akram Wisam, Nori Wassan, Abdul Ghani Zghair Muna. Metformin effect on internal carotid artery blood flow assessed by area under the curve of carotid artery Doppler in women with polycystic ovarian syndrome.. World journal of clinical cases. 2023. DOI: 10.12998/wjcc.v11.i6.1318.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.